5.2 UNIT REPLACEMENT
The unit replacement procedure is based on symptom analysis. According to the particular symptom
found by the
the units listed in Table 5-2 need to be replaced.
Table 5-2. List of Units
Unit Name
Description
Unit Code No.
Fuse (Fl)
125V/1 .25A (for 120V)
X50206 1050
(for
X 5 0 2 0 6 3 0 3 0
ROC Filter Unit
120V version
Y 5 6 5 5 0 3 0 0 0
120V 2 plugs version
Y 5 6 5 5 0 7 0 0 0
220V version
Y 5 6 5 5 0 4 0 0 0
240V version
Y 5 6 5 5 0 5 0 0 0
ROCX board unit
Control board
Y565201 000
board unit
Control panel
Y565501OOO
I
printer mechanism
Table 5-3 shows the flow chart to be referred to depending on the symptoms.
Table 5-3. Symptom and Reference Pages
Symptom
Problem Indicators
Reference
Page
Printer Does Not Operate
. No indicator on the control panel lights.
with Power Switch ON
. Carriage does not move.
5-4
Abnormal Carriage
. Carriage moves away from home position ‘at power ON.
Operation
. Although the carriage returns to the home position, the
5-5
printer does not enter READY mode.
Incorrect Printing (in self-
. No printing is executed.
test) with Normal Carriage
●
Some dots do not appear.
5-6
Operation
Abnormal Paper Feed
. No paper is fed.
. Separation between lines varies with irregular paper feed.
5-7
Abnormal Operation of
. No paper is fed (by operation of the LF or FF switch) in
Control Panel
OFF-LINE mode.
. No operation mode is set from the control panel.
5-8
. ON-LINE or OFF-LINE mode is not obtained.
Incorrect Printing in ON
. Carriage operates normally at power ON and the result of
LINE Mode
the self-test is correct. However, the print data from the
5-9
computer is not output normally.
5-3