Bit 7 (error flag) of the status byte is set to ‘‘1.’’
The appropriate bit in the extended status byte is set.
The scanner only accepts these commands: ESC F, ESC f, and ESC @.
Error recovery procedure:
After correcting the cause of the problem, perform one of the
following.
Turn the scanner off and then back on again.
Press the reset button (if the scanner model has a reset button).
Send the ESC @ command.
Set the parallel interface’s INIT signal to LOW.
Send a device reset message on your SCSI line.
Set the SCSI’s reset line to active.
Option error
When an option is installed and the ESC e (Control option) command
is enabled, this error occurs if the option does not operate properly.
Cause:
An option error is detected (cover open, paper jam, etc.).
Scanner’s response:
Bit 7 (error flag) of the status byte is set to ‘‘1.’’
The appropriate bit in the extended status byte is set.
Error recover procedure:
Correcting the cause of the error clears the error condition.
2-46
Command Usage
Summary of Contents for EMP-TW 1000
Page 4: ...iv ...
Page 11: ...Introduction Introduction 1 ...
Page 14: ...4 Introduction ...
Page 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Page 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Page 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Page 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Page 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Page 157: ...Command Reference 3 63 ...
Page 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Page 182: ...A 20 Interface Specifications ...
Page 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Page 268: ...B 86 Scanner Model Technical Data ...