Problem:
When connecting a different scanner model in your SCSI daisy
chain, an error message such as the following appears; ‘‘The
EPSON scanner is not connected.’’
Cause
When you sent the SCSI inquiry command, the
computer checked the scanner’s model name in the
Vendor Unique Parameter.
Solution
When checking the Vendor Unique Parameter, only
check the following underlined items:
...‘‘EPSON’’,20
H
,SCANNER,20
H,
‘‘GT-XXXX’’...
(B1
−
B4)
...‘‘EPSON’’,20
H
,20
H
,20
H
,SCANNER,20
H
,
‘‘GT-XXXX’’...
(B5, A5)
This ensures that information on a particular model
name is not checked by your program.
Problem:
Although you have attached a new scanner capable of a higher
resolution, you cannot achieve that resolution when scanning.
Cause
Your program is still using the scanning resolution
settings you obtained from the previous scanner
model.
Solution
Use the ESC I command to obtain the scanning
resolution values each time you scan.
2-52
Command Usage
Summary of Contents for EMP-TW 1000
Page 4: ...iv ...
Page 11: ...Introduction Introduction 1 ...
Page 14: ...4 Introduction ...
Page 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Page 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Page 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Page 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Page 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Page 157: ...Command Reference 3 63 ...
Page 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Page 182: ...A 20 Interface Specifications ...
Page 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Page 268: ...B 86 Scanner Model Technical Data ...