4. Control option (ESC e)
This command is effective only when an option has been installed on
the scanner. If you send these commands when no option is installed,
the scanner returns a NAK signal and a command error results.
You can check if an option is installed by either using the ESC f
command or by checking the option flag in the status byte.
When using the optional Automatic Document Feeder, you cannot
select color page scanning; you should always use the ESC C
command to select color line scanning, byte scanning, or monochrome
scanning.
If you send this command when using the optional Transparency Unit
or Automatic Document Feeder, the scannable area changes. Check
the extended status information to determine the new scannable area.
5. Eject (FF)
If you send this command when the Automatic Document Feeder is
installed, the scanner returns an ACK code and ejects the document
when scanning is completed.
Control Codes
These are commands that control data transfer.
1. Header (STX)
Send this code to indicate the beginning of a data block.
2-20
Command Usage
Summary of Contents for EMP-TW 1000
Page 4: ...iv ...
Page 11: ...Introduction Introduction 1 ...
Page 14: ...4 Introduction ...
Page 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Page 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Page 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Page 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Page 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Page 157: ...Command Reference 3 63 ...
Page 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Page 182: ...A 20 Interface Specifications ...
Page 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Page 268: ...B 86 Scanner Model Technical Data ...