5.
Following the order on the previous page, send the command to set
the scanning area and send any other commands necessary to
prepare for scanning. For details on these commands, see Chapter
3.
6.
Send the ESC f command. Check if the option is enabled and make
sure no error has occurred. In an error occurs, perform the proper
error recovery procedures.
7.
Send the ESC G (Start scanning) command.
8.
Receive the image data. If an error occurs during data reception, the
status byte’s error flag and area end flag are set to 1, and the byte
counter is set to 0; scanning then ends. After clearing the cause of
the error, send the ESC @ (Initialize the scanner) command to
reset the scanner and return to step 4.
9.
After image scanning is complete, send the FF (Eject document)
command (only if you are using the ADF).
10. To repeat scanning, return to step 6.
11. If you don’t plan to use an installed option, always send the ESC e
command to disable the option before you begin scanning.
Command Usage
2-25
Summary of Contents for EMP-TW 1000
Page 4: ...iv ...
Page 11: ...Introduction Introduction 1 ...
Page 14: ...4 Introduction ...
Page 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Page 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Page 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Page 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Page 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Page 157: ...Command Reference 3 63 ...
Page 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Page 182: ...A 20 Interface Specifications ...
Page 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Page 268: ...B 86 Scanner Model Technical Data ...