The Condition Data-Block
The GT-9000 sends the following data-block when it receives the
ESC S
(Request condition) command.
Condition Data-Block
Order of
bytes
Data
(in hex)
Contents
Explanation
(Information block)
1
02
STX code
Header: indicates the beginning of
the data-block
2
xx*
Status
Status byte: indicates the status of
the scanner
3
21
33 Bytes
Byte counter: indicates the number
of bytes of data
4
00
(Data)
1
43
‘‘C’’
Color mode
2
xx*
i
3
52
‘‘R’’
Resolution
4
xx
n1
(main scan resolution)
5
xx
6
xx
n2
(sub scan resolution)
7
xx
8
41
‘‘A’’
Reading area
(main scan offset length)
(sub scan offset length)
(main scan read length)
(sub scan read length)
9
xx
n1
10
xx
11
xx
n2
12
xx
13
xx
n3
14
xx
15
xx
n4
16
xx
17
44
‘‘D’’
Data format
18
xx
i
19
42
‘‘B’’
Halftoning mode
20
xx
i
Scanner Model Technical Data
B-67
Summary of Contents for EMP-TW 1000
Page 4: ...iv ...
Page 11: ...Introduction Introduction 1 ...
Page 14: ...4 Introduction ...
Page 36: ...Halftone mode C None Dither mode A Dither mode B Dither mode C Dither mode D 1 22 Overview ...
Page 39: ...Chapter 2 Command Usage 2 Command Usage 2 1 ...
Page 72: ...Color page scanning Use when sending color page data 2 34 Command Usage ...
Page 95: ...Chapter 3 Command Reference 3 Command Reference 3 1 ...
Page 131: ...Parameter range Default value i 00H center Command Reference 3 37 ...
Page 157: ...Command Reference 3 63 ...
Page 163: ...Appendix A Interface Specifications A Interface Specifications A 1 ...
Page 182: ...A 20 Interface Specifications ...
Page 183: ...Appendix B Scanner Model Technical Data B Scanner Model Technical Data B 1 ...
Page 268: ...B 86 Scanner Model Technical Data ...