ID Switch Setting
The SCSI ID is set with the ID switch mounted on the back of the
scanner.
The ID switch numbers correspond to the available ID and can be
set from 0 to 7. The numbers 8 and 9 should not be used.
Command Chart
This device uses the following group 0 processor commands.
Code
Command
Description
00H
TEST UNIT READY
Ready for operation confirmation
03H
REQUEST SENSE
Sense data request (*1)
08H
RECEIVE
Data transfer from target
0AH
SEND
Data transfer from initiator
12H
INQUIRY
SCSI device data request (*2)
*1 For sense data returned by the REQUEST SENSE command, only the extension
sense data format is supported.
*2 The INQUIRY data returned by the INQUIRY command is as follows:
Interface Specifications