Submenu
Function
s
"Hiding the Image and Sound Temporarily (A/V
Advanced
: The following items can be set.
•
BNC Sync Termination
: Set the termination for the
signal from the BNC port. This should usually be set to
Off
. Set to
On
when analog (75Ω) termination such as for
switchers is necessary.
•
Remote Control Type
: You can select
Normal
or
Simple
depending on the type of remote control.
Set this item to
Normal
to use the remote control
provided with this projector. When
Simple
is selected, you
can use the remote control provided with other Epson
projectors to operate this projector. This is useful if you
want to use a remote control that you are already familiar
with to operate the projector.
However, you cannot use the remote control provided
with this projector if this is set to
Simple
. Make sure that
the setting is correct because, if the projector is mounted
on the ceiling or somewhere hard to reach, changing it
back to
Normal
may be difficult. Additionally, you cannot
use the functions that are not equipped with this projector
or the remote control which you use.
•
Beep
: When this is set to
On
, the confirmation buzzer
beeps to notify you that the power turns on or off, or
cooling down is finished.
•
Indicators
: When set to
Off
, the projector's indicators are
turned off, except for abnormality or warning.
•
Log Save Destination
: Set the save location for the
projector's operation logs. Select
USB and Internal
Memory
to save logs to the USB flash drive connected to
the projector's USB-A port. Logs are saved as text files
(.log) to the USB flash drive.
•
Instant Off
: When set to
Enabled
, the projector goes into
standby status in approximately three seconds after Power
Off. If you turn the power on immediately after turning it
off, command communication may be cut off. To stabilize
Submenu
Function
command communication, set this to
Disabled
. When set
to
Disabled
, the projector goes into standby status in
approximately 75 seconds after power off.
•
Inv Direction Button
: Set this to
On
when the projector
is installed on a ceiling.
•
AC Voltage Monitoring
: When this is set to
On
, and the
projector is turned off by any method (including direct
shutdown) except for pressing the power button, an AC
Voltage Waring dialog is displayed the next time the
projector is turned on. Set this to
Off
if you use direct
shutdown regularly.
•
Lens Type
: When using the following lens, select the
model number of the lens.
ELPLS04, ELPLU02, ELPLR04, ELPLW04, ELPLM06,
ELPLM07, ELPLL07
Date & Time
: Make system time settings for the projector.
s
Lens Calibration
: Acquires the information of the lens
installed on the projector.
List of Functions
153
Summary of Contents for EB-L1490U
Page 1: ...User s Guide ...
Page 15: ...Introduction This chapter explains the names for each part ...
Page 58: ...Connecting Equipment 58 ...
Page 59: ...Basic Usage This chapter explains how to project and adjust images ...
Page 140: ...Configuration Menu This chapter explains how to use the Configuration menu and its functions ...
Page 219: ...Appendix ...