4.2.7.8 PG Sensor Removal
1. Remove the printer mechanism. (See 4.2.3 “Printer Mechanism Removal”.)
2. Release 2 hooks of the PG sensor securing it to the left frame with tweezers and
remove the sensor.
3. Disconnect the harness from the sensor (white).
Figure4-21. PG Sensor Removal
4.2.7.9 Release Lever Position Sensor Removal
1. Remove the printer mechanism. (See 4.2.3 “Printer Mechanism Removal”.)
2. Release 2 hooks of the release lever position sensor securing it to the right frame with
tweezers and remove the sensor.
3. Disconnect the harness from the sensor (blue).
Figure4-22. Release Lever Position Sensor Removal
A D J U S T M E N T
R E Q U I R E D
When the PG sensor is removed or replaced, perform the platen gap
adjustment and Bi-D adjustment.
Left frame
PG sensor (white)
Hook
C A U T I O N
When installing the release lever position sensor, be sure to insert it
between the release lever and the right frame.
A D J U S T M E N T
R E Q U I R E D
When the release lever position sensor is removed or replaced,
perform the platen gap adjustment and Bi-D adjustment.
Release lever position sensor (blue)
Summary of Contents for cLX-300+II RTP
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 85: ...C H A P T E R 5 ADJUSTMENT ...
Page 92: ...C H A P T E R 6 MAINTENANCE ...
Page 97: ...C H A P T E R 7 LX 300 IIRTP ...
Page 110: ...APPENDIX ...
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......