EPSON LX-300+II/300+II RTP/1170II
Revision D
Appendix
EEPROM Address Map
116
3CH
Panel mask pattern 2
b0: Font function
b1: (reserved)
b2: Pause function
b3: (reserved)
b4: (reserved)
b5: (reserved)
b6: (reserved)
b7: (reserved)
00H
00H
3DH
Copy mode
-----
-----
-----
Energy save mode
-----
-----
-----
b0: copy mode
0: Off
1: On
b1: (reserved)
b2: (reserved)
b3: (reserved)
b4: Energy save mode
0: On
1: Off
b5: (reserved)
b6: (reserved)
b7: (reserved)
00H
00H
3E,3FH
Tear-off adjustment
value
-432 to +432 (-25.4 mm (-1inch) to 0 mm
+25.4 mm (1inch), by 0.0588 mm (1/432 inch)
0000H
0000H
40H
Tear-off wait time
3 to 30 (by 0.1 sec.), 00H:3 sec.(same as default)
00H
(3 sec.)
00H
(3 sec.)
41H
Manual insertion wait
time
3 to 30 (by 0.1 sec.), 00H:1.5 sec.(same as
default)
00H
(1.5 sec.)
00H
(1.5 sec.)
42H-4FH (reserved)
All 00H
All 00H
Area 2
50H-51H (reserved)
00H
00H
52H-5AH
USB ID
All 00H
*a)
5BH-63H
All 00H
*a)
64H
Fatal error (Latest)
00H: Error is not recorded
30H: CR Error
32H: CG Error
33H: Head Low Volt Error
3AH: Head open Error
3BH: EEPROM Compare Error
00H
00H
65H
Fatal error (Record #1) (The same as the above)
00H
00H
66H
Fatal error (Record #2) (The same as the above)
00H
00H
67H
Fatal error (Record #3) (The same as the above)
00H
00H
68H-6AH
Sub-number for
customization
00H to 09H
000000H
(Standard)
000000H
(Standard)
6BH
(reserved)
00H
00H
6CH
Market CG
0:Standard version 1:NLSP version
00H
00H
Table A-13. EEPROM Address Map (continued)
Address
Explanation
Setting
QPIT
Settings
Factory
Settings
6DH
IBM character table
0:Table2 1:Table1
00H
00H
6EH
(reserved)
00H
00H
6FH
(reserved)
00H
00H
Area 3
70H
Vp adjustment value
*a)
*a)
71H
Vp adjustment value
(complement of 70H)
*a)
*a)
72H
Bi-d adjustment value
for high speed draft
mode
-12 to +12 by 0.0353 mm(1/720 inch)
00H
*a)
73H
Bi-d adjustment value
for draft mode
-12 to +12 by 0.0353 mm(1/720 inch)
00H
*a)
74H
Bi-d adjustment value
for NLQ mode
-12 to +12 by 0.0353 mm(1/720 inch)
00H
*a)
75H-7BH (reserved)
All 00H
00H
7CH
RPE (TOF) position
adjustment for
continuous
-128 to +127 by 0.0588 mm (1/432 inch)
00H
*a)
7DH
RPE (TOF) position
adjustment for
continuous
-128 to +127 by 0.0588 mm (1/432 inch)
00H
*a)
7EH
RPE (TOF) position
adjustment for
continuous
-128 to +127 by 0.0588 mm (1/432 inch)
00H
*a)
7FH
(reserved)
00H
00H
Table A-13. EEPROM Address Map (continued)
Address
Explanation
Setting
QPIT
Settings
Factory
Settings
Summary of Contents for cLX-300+II RTP
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 85: ...C H A P T E R 5 ADJUSTMENT ...
Page 92: ...C H A P T E R 6 MAINTENANCE ...
Page 97: ...C H A P T E R 7 LX 300 IIRTP ...
Page 110: ...APPENDIX ...
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......