EPSON LX-300+II/300+II RTP/1170II
Revision D
Troubleshooting
Troubleshooting
60
Table 3-3. Control Panel LED Does Not Light On.
Cause
Check Point
Y/N
Solution
Blowout of a fuse on
the power board.
Is a fuse on the power
board blown out?
YES
Check the electric circuit and
printer mechanism. If there is no
short circuit, replace the fuse.
Connector is not
connected to the
power board.
Are connectors
connected to the
power board
properly?
NO
Replace the power board.
Power switch is
defective.
Is conductivity of the
switch is OK?
YES
Replace the power board.
Power board is
defective.
Are +5VDC and
+35VDC OK when
the power is on?
NO
Replace the power board.
Power board and the
main board are not
connected properly.
Is CN8 connected
properly?
NO
Connect CN8 properly.
Main board is
defective.
-
-
Replace the main board.
Control panel harness
is not connected
properly.
Is the harness of the
control panel
connected properly?
NO
Connect the harness properly.
Control panel board
or harness is
defective.
-
-
Replace the control panel.
Table 3-4. Printer Mechanism Does Not Operate.
Cause
Check Point
Y/N
Solution
Any of CN3 to CN12
is not connected to the
main board properly.
Are all connectors
connected properly?
NO
Connect them properly.
Main board is
defective.
-
-
Replace the main board.
Printer mechanism is
defective.
-
-
Replace the printer mechanism.
Table 3-5. When Power is Applied, the Printer Becomes Fatal Error.
Cause
Check Point
Y/N
Solution
Carriage home
position error
(CR Error=30H)
Are CR motor, timing
belt, and CR home
position sensor
normal?
YES
Replace the power supply circuit
board.
NO
Replace the defective component.
CG access error
(CG Error=32H)
Is main board
normal?
YES
See Table 3-10, “Electrical Noise is
Caused.,” on page 62.
NO
Replace the main board.
Abnormal printhead
voltage
(Head Low Volt
Error=33H)
Is printhead voltage
(+42V line) normal?
YES
Replace the printhead.
NO
Replace the power supply board.
Abnormal printhead
temperature
(Head Open
Error=3AH)
Is the printhead
connected to the main
board properly?
YES
Replace the printhead.
NO
Connect the FFC properly.
CR motor harness is
not connected
properly.
Is CR motor harness
CN10 connected
properly?
NO
Connect it properly.
CR motor is defective.
-
-
Replace the CR motor.
HP detector harness is
not connected
properly
Is HP detector
harness CN3
connected properly?
NO
Connect it properly.
HP detector is
defective.
-
-
Replace the HP detector.
Power board is
defective.
Is power voltage
normal?
NO
Replace the power board.
-
-
-
Replace the main board and printer
mechanism.
Summary of Contents for cLX-300+II RTP
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 85: ...C H A P T E R 5 ADJUSTMENT ...
Page 92: ...C H A P T E R 6 MAINTENANCE ...
Page 97: ...C H A P T E R 7 LX 300 IIRTP ...
Page 110: ...APPENDIX ...
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......