7.1.5 Main Board Assembly Removal
1. Remove the upper housing. (See 7.1.2 “Upper Housing Unit Removal”.)
2. Remove the printer mechanism. (See 7.1.3 “Printer Mechanism Removal”.)
3. Remove 2 Jack Sockets (Torque 0.29-0.49 N.M.) securing the serial interface
connector to the lower shield plate.
4. Remove the serial interface connector from the installation hole of the lower shield
plate.
5. Remove 3 screws (C.P., Screw, 3x4 F/ZN; Torque 0.48-0.78 N.M.) securing the
parallel interface and USB interface to the lower shield plate.
6. Disconnect the panel FFC from CN12 on the board.
7. Disconnect the harness connected to the Cover Open Switch Assy from CN6 on
the board.
8. Disconnect the harness connected to the Power Supply Board Assembly from
CN8.
Press one edge of CN8 in order to remove or install the harness.
9. Remove 3 screws (C.B.P., Tite, 3x10 F/ZN) securing the main board assembly to
the lower housing.
Figure7-7. C640MAIN Board Assembly Removal
A D J U S T M E N T
R E Q U I R E D
When the main board assembly is replaced, perform the destination
setting, Bi-D adjustment, top margin adjustment, and bottom margin
adjustment.
Main Board Assembly
CN12
Serial interface connector
Jack Socket (Torque 0.29-0.49 N.M.)
C.P., Screw, 3x4 F/ZN
USB interface connector
Parallel interface
connector
CN6
CN8
C.B.P., Tite, 3x10 F/ZN
Summary of Contents for cLX-300+II RTP
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 85: ...C H A P T E R 5 ADJUSTMENT ...
Page 92: ...C H A P T E R 6 MAINTENANCE ...
Page 97: ...C H A P T E R 7 LX 300 IIRTP ...
Page 110: ...APPENDIX ...
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......