EPSON LX-300+II/300+II RTP/1170II
Revision D
PRODUCT DESCRIPTION
Control codes
31
1.5.3 Bi-Directional Commands
Reply printer ID
Reply printer ID:
[ESC][SOH]@EJL[SP]ID[CR][LF]
The printer sends the following ID string in reply to this command.
Enter / Exit Remote Mode
Enter Remote Mode:
[ESC](R[08H][00H][00H]REMOTE1
Exit Remote Mode:
[ESC][NUL][00H][00H]
Remote Commands
Change Printer Settings:
XX[nL][nH][00H][ml]...[mx]
Reply Printer Settings:
XX[nL][nH][01H][ml]...[mx]
XX is a string of 2 ASCII characters of defining a feature of the command. Following
[nL][nH] is two byte hexadecimal value that denotes the length of the [00H] and [ml]...[mx]
parameters. Last [m1] ... [mx] parameters are used to describe the detailed command
function and represent printer settings.
The printer sends the following string in reply to the commands of this type:
@BDC[sp]PS[CR][LF]
XX: Reply-Data;
[FF]
Table 1-30 shows the XXs that are provided in this printer.
<Remote commands>
-[Save] column shows whether SV commands are effective to each feature or not.
-
: All parameters are saved.,
Δ
: Some limited parameters are saved.,-: No parameter is
saved.
*1 Only for customized models.
*2 m1=0 to 1 only
*3 Only the following parameters are stored in memory. (Table 1-31)
@EJL[SP]ID[CR][LF]
MFG: EPSON;
CMD: ESCP9, PRPII9,BDC;
MDL: LX-300+II;
CLS: PRINTER;
DES: EPSON[SP]LX-300+II;
[FF]
@EJL[SP]ID[CR][LF]
MFG: EPSON;
CMD: ESCP9,PRPII9,BDC;
MDL: LX-1170II;
CLS: PRINTER;
DES: EPSON[SP]LX-1170II;
[FF]
LX-300+II
LX-1170II
Table 1-30. Bi-Directional Commands
Function
Code/ Parameter
Save
Enter Remote-1
ESC”(R”08H 00H 00H “REMOTE1”
-
Exit Remote-1
ESC 00H 00H 00H
-
Save settings
“SV” 00H 00H
-
Initialize
“RS” 00H 00H
-
Load power-on default
“LD” 00H 00H
-
Select typeface
“FO” 02H 00H 00H m1
m1=0(Roman), 1(Sans serif), 5(OCR-B)*1
Δ
*2
Select character pitch
“CP” 02H 00H 00H m1
m1=0(10cpi), 1(12cpi), 2(15cpi), 3 (17.1cpi),
4(20cpi), 5(Propotional)
Select draft or NLQ
“CQ” 02H 00H 00H m1
m1=0(Draft), 1(NLQ), 2(High speed draft)
Select character table
“CT” 02H 00H 00H m1
m1=0 (Table0), 1(Table1)
Δ
*3
Assign character table
“AT” 04H 00H 00H m1 m2 m3
m1=0(Table0), 1(Table1)
m2, m3=(ESC/P2 Character Table No.)*4
Δ
*3
Select an international
character set
“IC” 02H 00H 00H m1
m1=0(U.S.A), 1(France), 2(Germany), 3(U.K.)
4(Denmark1), 5(Sweden), 6(Italy), 7(Spain1),
8(Japan), 9(Norway), 10(Denmark2), 11(Spain2),
12(Latin America)
Δ
*5
Turn 1 inch skip perforation
on/off
“SK” 02H 00H 00H m1
m1=0(off), 1(on)
Summary of Contents for cLX-300+II RTP
Page 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Page 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 85: ...C H A P T E R 5 ADJUSTMENT ...
Page 92: ...C H A P T E R 6 MAINTENANCE ...
Page 97: ...C H A P T E R 7 LX 300 IIRTP ...
Page 110: ...APPENDIX ...
Page 127: ......
Page 128: ......
Page 129: ......
Page 130: ......