EPSON AcuLaser C9200N
Revision D
DISASSEMBLY AND ASSEMBLY
Main Unit Disassembly/Reassembly
188
Confidential
PH Unit
When replacing the PH Unit, replace four units at the same time.
Even when the single Unit needs to be replaced, replace four units.
1. Remove three Screws [1], three Connectors [2], and three Photoconductor Unit Guide rails
[3].
D10
[1]
[2]
[3]
4038F2C106DA
When installing the Photoconductor Unit Guide rail, insert its end correctly to the
mounting hole in the Main Unit side.