E640: COLOR SHIFT TEST PATTERN FAILURE
E641: COLOR SHIFT ADJUST FAILURE
Relevant Electrical Parts
Transfer Belt Unit
IDC Sensor
Photoconductor Unit
PH Unit
Step
Action
Connection Diagram
Control Signal
Location
(electrical parts)
1
Check if Transfer Belt has damages
and correct as necessary.
---
---
2
Check that the IDC Sensor is properly
installed and correct as necessary.
---
---
3
Check if the IDC sensor is dirty and
correct as necessary.
---
---
4
Check the IDC Sensor connector for
proper connection and correct as
necessary.
---
---
5
Check the PWB-M connector for
proper connection and correct as
necessary.
---
---
6
Change the cable that connects IDC
Sensor and PWB-M.
7
Change IDC Sensor.
(p.210)
8
Change Photoconductor Unit.
(p.162)
9
Change PH Unit.
(p.175)
---
---
Relevant Electrical Parts
PH Unit (displacement)
Transfer Belt Unit
Step
Action
Connection Diagram
Control Signal
Location
(electrical parts)
1
Execute the correction of skew.
(p.315)
---
---
2
Check if Transfer Belt has damages
and correct as necessary.
---
---
Summary of Contents for Aculaser C9200N
Page 1: ...SERVICE MANUAL A3 Color Laser Printer EPSONAcuLaser C9200N SEPG08001 Confidential ...
Page 11: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Page 31: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Page 96: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Page 156: ...Confidential C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Page 313: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Page 331: ...Confidential C H A P T E R 6 MAINTENANCE ...