Check the connection status and stain on high voltage point between Photoconductor unit and High voltage unit.
Figure 3-1. High voltage point on Photoconductor unit
Figure 3-2. High voltage point on High voltage unit
Reset Photoconductor unit.
Correct connection
status
Clean high voltage
point
Go to Step 3
3
Check the installation status of PH unit.
Correct installation
Go to Step 4
4
Check the operation of Photoconductor unit.
Exchange
Photoconductor unit
Go to Step 5
Table 3-19. Troubleshooting