Web admin interface
68
VGA2Ethernet User Guide
On the Web admin interface, select Frame Grabber to configure frame grabber
adjustments. The VGA2Ethernet device automatically adjusts image capture settings
every time it starts up. The automatic image adjustment is repeated every 60 seconds
during operation. You can change the interval between automatic adjustments if you
want them to occur more or less often. The capture settings attempt to produce the
best quality captured image for the equipment used in your applications.
Normally you would not have to make manual image adjustments. However, you may
have special requirements or for other reasons have image quality problems that may
only be fixed by making image adjustments.
The Web admin interface contains most of the information that you need to make
image adjustments including a brief description of the effect of each adjustment and
the adjustment range.
-
To make an adjustment, add a value to one or more fields and select
Apply.
-
To clear any adjustments, delete the value from one or more fields and select
Apply. To have changes take effect, you must reboot the VGA2Ethernet
device (see
“
Rebooting or Restarting
VGA2Ethernet
”
)
.
You can make more
than one change before selecting Apply and rebooting.