4
Loosen the screw (
A
) from the defective tubular heating element.
5
Disconnect the connections from the flat pins and remove the defective
tubular heating element.
6
Insert the new tubular heating element and use a silicone seal and the
pressure plate to tighten it in place.
Check the old silicone seal and reseal as needed.
The screw must be screwed in tightly so that water cannot seep into
the terminal box.
7
Attach the flat plug again.
Ensure that it is firmly in place to eliminate the risk of fire.
8
Place the cover on the terminal box and tighten the screws.
9
Insert the heating coil.
See
A
Crosshead screw
B
Terminal block
C
Silicone seal
D
Pressure plate
E
Flat pin
B
A
E
C