EOS Zeus S / EOS Zeus SL - Installation and Operating Instructions
EN-15
Identification
Electrical connection – fuse protection
Heater
Heater
output
Connection
mains –
control unit
Connection
control
unit –
heater
Connection
mains –
output
controller
Connection
output
controller –
heater
Connection
control
unit –
output
controller
6.0 kW
5 x 2.5 mm
2
5 x 1.5 mm
2
-
-
-
7.5 kW
9.0 kW
10.5 kW
5 x 2.5 mm
2
5 x 1.5 mm
2
4 x 1.5 mm
2
12 kW
Heater output
Fuse protection for
control unit
Fuse
Output controller (LSG)
6.0 kW
3 x 16 A
-
7.5 kW
9.0 kW
10.5 kW
3 x 16 A
12 kW
Heater
output
Unit
dimensions
Ø x H in cm
Weight
without rocks
Zeus S/
Zeus SL*
Stone filling
Output
controller (LSG)
6.0 kW
Ø 45 x 100 mm
*Ø 45 x 70 mm
67 kg
*62 kg
25 kg
-
7.5 kW
9.0 kW
10.5 kW
68 kg
*63 kg
LSG 9
LSG 18
12 kW