EOS Zeus S / EOS Zeus SL - Installation and Operating Instructions
EN-17
Installation
3
Installation
This chapter describes how to install the Zeus S/SL. Prior to installing the
unit, air inlets and outlets must be installed in the cabin. It may be neces-
sary to mount additional fans in the inlets/outlets. All protective films must
be removed.
NOTICE
Damage due to incorrect mounting location
The heater is not suitable for outdoor use.
The heater must be operated only inside buildings and may not
be exposed to environmental conditions such as extreme hu-
midity and moisture or the possible formation of condensation
or corrosive substances in the ambient air, as well as other
weather conditions.
The heater is not designed to be installed or set up in an alcove
or under a bench or sloping roof.
3.1
Specifications for the cabin
The cabin must be planned and installed according to specifications before
the sauna heater is installed.
The floor on which the sauna heater stands must be level. In general, it
should be noted that the sauna heater must not be set on a floor made of
highly flammable material (laminate, flooring made of plastic material,
etc.). Ceramic tiles are recommended as a flooring option.
Electrical lines
All electrical installations laid inside the cabin must be suitable for silicone
cables and a temperature of at least 170°C.
All lines must be routed in such a way that they are well-protected, e.g. in a
cable duct.
If single-core lines are used as connecting cables, they must be protected
by a flexible metal hose that is connected to the protective conductor.