Technical Data
4.1
Mechanical Data
Envision One cDLM®
Length
392 mm
Width
430 mm
Height
775 mm
Weight
32.5 kg
Build Envelope
180mm x 101mm x 175mm
Projector Resolution
1920 px x 1080 px
XY Resolution
93 µm
Dynamic Z Resolution
25-150 µm
Data Handling
STL
Warranty
1 year back to factory included
4.2
Electrical Requirements
We strongly recommend you use an uninterrupted power supply to protect your printer. All electrical requirements
must be met to ensure the most stable setup:
1. Ensure there is a sufficient clean electrical socket that fluctuates no more than +/-3% (EU: +/-5%) from
its baseline.
2. Do not plug any additional equipment into the power circuit.
3. The Envision One requires 110 volts with no less than 5 amps.
4. The oxygen concentrator requires 120 volts with no less than 3 amps.
5. Oxygen Concentrator:
Power supply:
220V ± 22V, 50Hz ± 1Hz/110V ± 15V, 60Hz ± 1Hz
Operation
voltage (V/Hz)
: AC220/50 AC110/60
6. Plug the printer and oxygen concentrator into separate surge protectors or separate battery backups.
7. The Envision One does not require a dedicated server. It can be connected wirelessly, hard-wired into
the network, or directly connected to a computer.
WARNING!
Risk of injury! Risk of damage to the printer!
Failure to use the grounding devices may lead to damage or injuries!
•
Connect ground wire before using!
•
Only use the grounding adapters of the plug & socket type targeted for the country of intended
use of the printer!
Grounding of electrical receptacles is an important safety feature that minimizes the risk of electric shock and
protects electrical equipment from damage. For proper operation and in order not to disrupt the operation of the
printer, ground the printer before start working with it!
Figure 1: Grounded plug and outlet for Europe