54
Trouble Shooting
Table 9:
Troubleshooting
Problem
Possible Cause
Solution
Locking
conditions
Reset the Proflame IFC board
· Turn the system off by pressing the ON/OFF button on
the transmitter
· After approximately 2 seconds press the ON/OFF button
on the transmitter again.
· In the manual flame control mode, use the down arrow
button to reduce the flame to off, indicated by the word
OFF displayed on the transmitter LCD screen.
· Wait approximately 2 seconds and press the up arrow
button, the ignition sequence will start.
Main burners
will not start
The pilot flame has gone out
· See “Pilot will not remain lit”
The remote control is not working
correctly
· Replace the batteries
The thermostat is disconnected or
set too high
· Set the thermostat to a lower temperature
Problem with thermopile circuit
· Check gas line pressure
· Check wiring to thermostat for breaks
· Check for flame impingement on thermopile
Flame lifting
Leak in vent pipe
· Check for leaks in vent connections
Improper vent configuration
· Check vent configuration with manual
Terminal may be re-circulating flue
gases
· Check to see if terminal is on correctly
· May need to install high wind termination cap.
· Contact dealer
Blue Flames
The heater has just been started
· Normal during start up: flame will yellow as the fireplace
heats up
Improper air shutter adjustment
· Adjust air shutter – contact your dealer
Glass fogs up
Normal condition: after the
appliance warms up the glass will
be clear.
**Due to additives in gas, glass may get hazy during
operation** Clean as needed.
Flames are
burning
“dirty” or
sooting
The logs are placed incorrectly
· Check log positioning
Improper air shutter adjustment
· Increase primary air by opening the air shutter and/or by
opening the vent restrictor
· Check for proper venting and blockage of the vent
termination
· See also “Burners will not remain lit”
Incorrect rating input
· Check manifold pressure and clock input rating for over-
firing
If a particular flame is curving excessively your burner media not be evenly distributed
creating an abnormal draft on the flame; position burner media infront of the secondary
air slots in the affected area to slow down the draft. You can fine tune the flame this way
to ensure healthy flame appearence.
Note: For C34ID specific troubleshooting refer to the Dexen user manual supplied