DO NOT USE
Central presence sensor test
Inner impulse (motion) monitoring
Side presence sensor test
Side presence sensor 2
Stop
Side presence sensor 1
Blocking device
Blocking device
(+) 24V
Inner side opening
(-) 0V
(+) 24V
Key opening
Central presence sensor 2
Central presence sensor 1
(-) 0V
(+) 24V
Outer side opening
Jumper the unused N.C. contacts
(-) 0V
blocking device connection
(main coil)
}
7
6
5
4
3
2
1
14
13
12
11
10
9
8
17
16
15
20
19
18
(use this contact if used only one sensor)
(use this contact if used only one sensor)
8.2 Control panel commands
NOTE
: Power supply output for external
accessories 24V .
0,64 A: DAS200;
1 A: DAS200HD-DAS200RF-DAS200RG.
The maximum absorption of corresponds
to the sum of all terminals power supply
output (1-7; 8-14; 15-17)
8.2.1 Commands
Contact
Description
1
2
(ref. parameter 27)
N.C.
SIDE
PRESENCE
SENSOR 1
Connect side presence sensor 1 as shown in the example in
paragraph 12.
1
3
(ref. parameter 46)
N.C. STOP
The opening of the safety contact causes the current operation
to stop.
WARNING
: when the contact closes again, the door closes.
WARNING
: The emergency opening (battery 12V), is priority
(=door opens in case of mains power failure even if STOP
contact is open).
1
4
(ref. parameter 28) N.C.
SIDE
PRESENCE
SENSOR 2
Connect side presence sensor 2 as shown in the example in
paragraph 12.
1
5
N.O.
OUTER SIDE
OPENING
Connect the external sensor as shown in the example in pa-
ragraph 12.
The closure of the contact activates the door opening operation.
6
(ref. parameter 29)
SIDE
PRESENCE
SENSOR TEST
Connect the test clamp of the side sensors.
Clamp 6 activates a test on the side safety sensors before every
operation.
If the test fails, an alarm message appears on the display.
1
-
7
+
POWER SUPPLY
TO
ACCESSORIES
24 V accessories power supply.