30
IP2266EN
EN
i
NOTE
: for DAS200RF follow the start up procedure indicated in the DAS200RFKA kit
manual.
Before performing any type of operation, make sure that the automation is turned off
and the batteries are disconnected.
Start-up and adjustment must be performed in the following order when the automation is installed:
1.
Connect the accessories, opening and safety sensors, blocking device, batteries and selector.
2.
Jumper the safety contacts
1-2
,
1-3
,
1-4
,
8-9
,
8-11
on the control panel and
1-5
on plus
module DAS902MP, if not used.
3.
Connect the mains power supply to the automation.
4. Set the following parameters
:
Parameter
Description
Settings
05
Lock configuration (main control)
Set ONLY if installed bistable lock DAS802LOKB. 12= bistable
lock.
10
= No lock.
11
= Antipanic lock (locked with power – LDP).
12
= Standard lock (locked without power – LD) and bi-
stable lock (LDB).
09
Central presence sensor test
00
= None (factory setting).
01
= Presence sensor 1 (set if a presence sensor with
monitoring is installed).
02
= Presence sensor 1 and 2 (set if two presence sensors
with monitoring are installed).
12
Selection of opening direction
00
= right hand opening for single door wing automation.
01
= left hand opening for single door wing automation and
for double door automation (factory setting).
16
Inner Impulse (motion) Monitoring
According to EN16005 or DIN18650 it is a demand to have
Inner impulse monitoring= On in escape routes.
00
= Disables monitoring.
01
= Enables monitoring.
NOTE
: on DAS200RF set to 01.
NOTE
: on DAS200RG this parameter is set to 01.
29
Side presence sensor test
00
= None ( factory setting)
01
= Presence sensor 1 (set if a presence sensor with
monitoring is installed).
02
= Presence sensor 1 and 2 (set if two presence sensors
with monitoring are installed).
67
Selection of the type of automation
00
= Automation with one door wing.
01
= Automation with two door wings.
98
Lock Configuration, terminal 16-17
DAS902MP
NOTE
: Set ONLY if installed bistable lock DAS802LOKB.
11
= bistable lock
i
NOTE
: Parameter 10 ( Emergency Unit Monitoring ) on DAS00RG is not visible and it is
set up on
02
= redundant monitoring