33
IP2266EN
EN
11. Parameters
11.1
Configuration parameters according to function
For more information on the parameters, see paragraph 9.2
SPEED parameters
Parameter
Description
Range
00
High speed opening
10÷70cm/s
01
Low speed
05÷70cm/s
02
High speed closing
10÷70 cm/s
TIME parameters
Parameter
Description
Range
03
Hold open time
00÷60s
04
Key hold open time
00÷60s
20
Partial hold open time
00÷60s
21
Push & Go hold open time
00÷60s
22
Auto width activation time
00÷60s
23
Auto width resume time
00÷60s
24
Jam hold time
00÷10s
25
Interlock disable time
00÷60s
26
Presence hold open time
00÷60s
92
(DAS902MP)
Open/Close timeout ref. terminal 4
00÷03
FUNCTION parameters
Parameter
Description
Range
5E
Status indication. Off (00) / On (01)
00÷01
5F
Default programming. Off (00) / On (01)
00÷01
12
Opening direction. 1 wing Right (00) / 1 wing Left or 2 wings (01).
On DAS200RG not selectable
00÷01
13
Hold force
00÷60N
2A
Side presence function. Safe speed (00) / Stop door (01)
00÷01
32
Active brake on stop. Off (00) / On (01)
00÷01
33
Push & Go in EXIT mode selection. Off (00) / On (01)
00÷01
34
Hold force in EXIT and OFF mode selection. Off (00) / On (01)
00÷01
35
Toggle operation mode selector after stop. Off (00) / On (01)
00÷01
53
Operator type. Slider (00) / mechanical emergency unit DAS200RF (04)
00÷04
54
Service Needed Operating Hours
00÷60h x 1000
55
Service needed opening cycles
00÷50 x
100.000
60
Learn. Off (00) / On (01)
00÷01
61
Auto width. Off (00) / On (01)
00÷01
65
Sustainable Drive Mode. Off(00) / On(01)
00÷01
6A
Interlock function. Off (00) / On (01)
00÷01
6B
Synchronizing Function. Off(00) / On(01)
00÷01
6C
External bus device ID
00÷99