24
IP2266EN
EN
Contact
Description
8
9
(ref. parameter 07)
N.C.
CENTRAL
PRESENCE
SENSOR 1
Connect central presence sensor 1 as shown in the example
in paragraphs 12.
10
(ref. parameter 16)
INNER IMPULSE
(MOTION)
MONITORING
Connect the test clamp of the escape route. If the test fails, an
alarm message appears on the display.
8
11
(ref. parameter 08)
N.C.
CENTRAL
PRESENCE
SENSOR 2
Connect central presence sensor 2 as shown in the example
in paragraph 12.
8
12
(ref. parameter 04)
N.O. KEY OPENING
Closing the contact via a key command activates an opening
operation and a closing operation after the time selected by
parameter 04.
If used for opening in DOOR CLOSED mode:
•In the presence of a mains power supply or continuity batteries,
a 8-12 command partially opens the door and closes it after
the time selected by parameter 04.
•If there is no mains power supply, a 8-12 command reactivates
the batteries, if present, for the time required to perform a com-
plete opening operation and then the batteries are disconnected
from the control panel.
13
(ref. parameter 09)
CENTRAL PRE-
SENCE SENSOR
TEST
Connect the test clamp of the presence sensors.
Command 13 activates a test on the central safety sensors
before every operation. If the test fails, an alarm message
appears on the display.
8
-
14
+
POWER SUPPLY
TO
ACCESSORIES
24V accessories power supply.
15
16
N.O.
INNER SIDE
OPENING
Connect the internal sensor as shown in the example in pa-
ragraph 12.
The closure of the contact activates the door opening operation.
15
-
17
+
POWER SUPPLY
TO
ACCESSORIES
24V accessories power supply.
18
19
(ref. parameter 05)
BLOCKING
DEVICE
CONNECTION
(main coil)
Output for connecting an electro-mechanical block (optional).
The blocking device is automatically selected during the learning
phase (except bistabel lock).