INTELLIGEN LV DISPENSE SYSTEM
13
Installation and Use Manual | Entegris, Inc.
5. Slide in a new filter.
WARNING! PINCH HAZARD! Keep
fingers clear of jaw mechanism to
prevent personal injury.
6. Keep fingers
CLEAR
of the jaw mechanism,
then lower the lever until the tab clicks into
place on the filter.
Step 6: Connect Fluid Lines
Minimize tubing lengths whenever possible and
maximize fluid tubing size wherever practical to
further reduce pressure drop through the tubing.
Use the shortest practical tube length, while
providing adequate service loops.
As a rule, minimize the distance between the liquid
source and the system, and between the system and
the point-of-dispense.
CAUTION! DRIP HAZARD! Do not over-tighten
fittings. Excessive force will damage the internal
seals. Tighten the fittings by hand, then use a
small adjustable wrench to tighten for the final
1⁄4 turn.
1. Insert Pillar sleeve and tube assembly into the
fluid fitting adapter.
2. Hand tighten Pillar nut.
3. Use 13 mm wrench to hold the fluid fitting adapter
to prevent it from turning when tightening the Pillar
nut, sleeve, and tube assembly.
NOTE: This is to hold the nut. DO NOT tighten.
4. While holding the fluid fitting adapter with the
13 mm wrench, tighten the Pillar nut to specified
Super 300 Type Pillar manufacturing instructions.
CAUTION! Refer to Super 300 Type Pillar
Fitting Instruction Manual No. 048L-1 for
fitting insertion instructions.