ENFORCER Indoor Proximity Card Reader
SECO-LARM U.S.A., Inc.
15
To delete a super user card:
Step Action
Reaction
1
Tap the master card 5 times
Blue status LED flashes, and LED 5
flashes once
2
Wait 2 seconds
2 Beeps, then LEDs 1 and 2 flash
3
Press the “Bell” button twice
LED 2 turns to a steady ON to indicate
that the reader is in the delete super user
mode
4
Wait 2 seconds
2 Beeps; all five LEDs flash to indicate
that the reader is ready to delete a super
user card
5
Press the “Bell” button 1 to 5 times to
choose a user group
The super user card’s user group LED
turns to a steady ON
6
Wait 2 seconds
2 Beeps
7
Press the “Bell” button once
2 Beeps confirm that the super user card
was deleted
6
Exit programming by tapping the master
card once
2 Beeps
NOTE:
After deleting a super user card, that card may be reused like any blank card.
Troubleshooting:
The LEDs do not light
Check the power connection
Check the power supply
The relay does not activate
Make sure you are using a valid user card
Make sure the relay is not in toggle mode
Make sure the correct relay output is being used
(either N.O. or N.C.)
The relay time is too short
Set a longer door-release time
The egress button is not
working
Make sure you are using a N.O. switch
Double-check the door-release time
Double-check the relay toggle mode
Advanced Programming (continued):