ENFORCER Indoor Proximity Card Reader
8
SECO-LARM U.S.A., Inc.
Basic Programming:
Most businesses will require basic programming of a super user card and a limited number of user
cards. Follow the programming instructions on this page if the owning company fits these
requirements:
Max. 100 user cards
Max. 1 super user card
No need to change the default settings of the proximity card reader
NOTE:
If more advanced programming is required, see “Advanced Programming” on page 10.
1.
Program the master card (see page 7).
2.
Program the user cards:
Step Action
Reaction
1
Tap the master card 1 time
Blue status LED flashes, and LED 1 flashes
once
2
Wait 2 seconds
2 Beeps, then LEDs 1 through 5 flash
3
Press the “Bell” button once
LED 1 turns to a steady ON
4
Wait 2 seconds
2 Beeps
5
Tap a blank user card 1 time
2 Beeps
6
For multiple user cards, repeat step 5
2 Beeps for each card confirms that the card
was programmed into the reader
7
Exit programming by tapping the
master card once
2 Beeps
NOTE:
Do not program the same card twice. Once a card has been programmed, attempts to
program that card will be rejected with a single long beep of the proximity card reader.
3.
Program the super user card:
Step Action
Reaction
1
Tap the master card 5 times
Blue status LED flashes, and LED 5 flashes
once
2
Wait 2 seconds
2 Beeps, then LEDs 1 and 2 flash
3
Press the “Bell” button once
LED 1 flashes once
4
Wait 2 seconds
2 Beeps, then LEDs 1 through 5 flash
5
Press the “Bell” button once
LED 1 turns to a steady ON
6
Wait 2 seconds
2 Beeps
7
Tap a blank user card 1 time
2 Beeps
8
Exit programming by tapping the
master card once
2 Beeps