![Enerpac SLVS-8 Instruction Sheet Download Page 8](http://html1.mh-extra.com/html/enerpac/slvs-8/slvs-8_instruction-sheet_2411239008.webp)
8
8.0 ELECTRICAL COMPONENT ASSEMBLY
(Refer to Figures 1 and 2)
NOTE:
An indelible marker and tie wraps with tabs are provided to
allow all cables to be labeled.
1.
Remove the ELECTRO-BOX from the shipping container and
make sure the power switch is on the "OFF" position. Depress
the EMERGENCY STOP
(A)
button to ensure that it’s
deactivated. Connect the power cord to the ELECTRO-BOX.
Figure 4
2.
Connect the cable from the junction box for PUMP
DIRECTIONAL CONTROL VALVE to the receptacle on the
side of the ELECTRO-BOX labeled "PUMP"
(B)
.
Figure 5
3.
Connect the pressure transducer cable from the VALVE
MANIFOLD JUNCTION BOX to the ELECTRO-BOX
receptacle labeled “MANF1 PRESS TRANS”
(C)
.
Figure 6
4.
Connect the valve cable from the MANIFOLD JUNCTION
BOX to the electro-box receptacle labeled “MANF1 VALVES”
(D)
.
Figure 7
5.
Connect the cable from the PC Port labeled "ANALOG" to the
receptacle on the side of the ELECTRO-BOX labeled
"COMPUTER ANALOG 1"
(E)
.
Figure 8
6.
Connect the cable from the PC to the receptacle on the side
of the ELECTRO-BOX labeled "COMPUTER RELAYS"
(F)
.
Figure 9
7.
Place a STROKE SENSOR at each lift point. Connect a
SENSOR CABLE to the sensor receptacle to the receptacle
labeled "SENSOR 1"
(G)
, for example. The sensor placed at
lift point #1 must be connected to the ELECTRO-BOX sensor
input receptacle #1. Repeat this procedure for all remaining lift
points. Identification tags are supplied with the ELECTRO-
BOX and can be affixed to the cables to aid cable identification
and hook-up.
Summary of Contents for SLVS-8
Page 99: ...99 L2543 O 08 01...
Page 100: ...100...
Page 101: ...101...
Page 102: ...102...
Page 103: ...103...
Page 104: ...104...
Page 105: ...105...
Page 106: ...106 F E A C B D G...
Page 107: ...107...
Page 108: ...108...
Page 109: ...109...
Page 110: ...110...
Page 111: ...111...
Page 112: ...112...