B/E AEROSPACE
COMPONENT MAINTENANCE MANUAL
4521
Page 8001
26 May 2015
25-34-80
Use or disclosure of information on this page is subject to
the restrictions in the proprietary notice of this document.
FITS AND CLEARANCES
TASK 25-34-80-940-801-A01
1.
General
A. This section contains the fits and clearances that are necessary for the Water Boiler.
B. Torque values are listed in Table 8001.
TASK 25-34-80-99A-010-A01
Table 8001
Torque Values
ITEM
TORQUE VALUE
FT-LB/IN-LB
N•m
Heater Assemblies (90 or 90A, IPL Figure 3)
9.5 to 10.5 ft-lbs
12.89 to 14.23
Screws (135, IPL Figures 2 and 2A)
10 to 12 in-lbs
1.2 to 1.4
Nut, Faucet (340, IPL Figures 2 and 2A)
170 in-lbs
19.20