B/E AEROSPACE
COMPONENT MAINTENANCE MANUAL
4521
Page 1004
26 May 2015
25-34-80
Use or disclosure of information on this page is subject to
the restrictions in the proprietary notice of this document.
D. POWER and LOW WATER Button Light Test
(1)
Connect the UUT to the 115 VAC ± 3 Volts, 400 Hz test bench power supply and activate the
power.
(2)
Turn the UUT power ON.
(3)
Make sure that the ON/OFF and LOW WATER indicator illuminates. Check both heaters and the
READY light indicator have NOT activated.
(4)
Turn the UUT power OFF.
(5)
Turn the test bench power OFF.
(6)
Capacitor and Triac Test
(a)
Install the Multi Test Box (refer to Table 1001) between J4 and P4.
(b)
Manually open the C.B. on the Multi Test box (refer to Table 1001).
(c)
Check the Multi Test Box temperature switch is set to 205 °F (96 °C).
(d)
Turn the test bench power ON.
GRAPHIC 25-34-80-99B-003-A01
Figure
1001
Test Setup
PRESSURE
REGULATOR
HAZARD
GROUND
FLOW METER
(0-2 GPM)
CIRCUIT
BREAKER
10 AMP
0-15 AMP AC
0-15 AMP AC
0-15 AMP AC
WATER
BOILER
A
ØA
115 VAC
400 HZ
ØB
115 VAC
400 HZ
ØC
115 VAC
400 HZ
AC NEUT
FRAME GND
WATER
SUPPLY
DRAIN
V
V
V
CIRCUIT
BREAKER
10 AMP
CIRCUIT
BREAKER
10 AMP
I
I
I
B
C
D
E
F
G
(0-200 PSI)
(0-1378.95 KPA)
SHUT-OFF
VALVE
PRESSURE
GAUGE