B/E AEROSPACE
COMPONENT MAINTENANCE MANUAL
4521
Page 7015
11 Jul 2018
25-34-80
Use or disclosure of information on this page is subject to
the restrictions in the proprietary notice of this document.
(k)
Install two screws (175), four flat washers (180), two flat washers (185) by applying Alodine
(refer to Table 7001), and two lock nuts (190) to attach the connector harness
assembly (150) grounding wires SG1 and SG2 to the water boiler chassis (525).
NOTE:
Do not attach the rear support assembly (120) until after the installation of
molded module housing (130).
(l)
Attach rear support assembly (120) to water boiler chassis (525) with two screws (135),
lock washers (140), and flat washers (145). Torque screws (135) to 10 to 12 in-lbs
(1.2 to 1.4 N•m).
(m)
Secure rear support assembly (120) to water boiler chassis (525) with four screws (125).
GRAPHIC 25-34-80-99B-013-A01
Figure 7009
Lock Down Arm and Rail Lock Block
165
120
170
145
140
135
150
160