Generator ESE 607 / 957 DBG (ES) DIN maintenance
Maintenance work
Issued: February 2013
ESE 607 / 957 DBG (ES) DIN
69
6.2.3 Replacing
fuses
Replacing fuses (only for the special accessory external start
socket, socket, charging retention and/or remote start device)
1. Open the fuse holder.
2. Replace the fuse.
3. Close the fuse holder
Fuse is replaced.
Figure 6-4: Replacing a fuse
Fuse type
Amperes
needed for
2
20
Control system
2
15
Charging retention socket
1
150
External start (Nato) socket
Table 6.2: Location of the fuses