Operating the ESE 607 / 957 DBG (ES) DIN
Starting the generator
Issued: February 2013
ESE 607 / 957 DBG (ES) DIN
39
REFERENCE NOTE
Only activate the starter brie
fl
y (max. 5 - 10 seconds). Never start
or run the engine with the battery disconnected.
4. Move the choke
(Figure 4-1-(1))
back into its start position.
The engine has started.
REFERENCE NOTE
The electrical consumer needs a heating up phase of approx.
one minute to connect up and switch on.
alternatively upon failure of the electrical start:
(a manual start can be realised more easily by two people)
MANUAL START
1. Open on
fl
ap side
(see Figure 4-1-(1))
.
2. Pull on the choke (completely for a cold engine / appropriately
less for a warm engine) and hold
fi
rmly.
3. Set the START-STOP switch
(Figure 4-2-(1))
to position „1“
4. Pull the reversing starter next to the handle
(Figure 3-3-(3))
.
REFERENCE NOTE
Place your foot on the unit‘s frame to support yourself
and make it easier to pull the starter.
The engine starts.
5. Move the choke slowly back into its start position.
The engine has started.
WARNING!
Generators with remote controls are
fi
tted with an
automatic choke. You do not need to use the manual choke
(on the engine).
HAND START (or use the
special accessory remote
start device)
1. Set the START-STOP switch
(Figure 4-2-(1))
to position „1“
2. Flap above or
fl
ap at the side fully open.
3. Push the choke lever on the engine to the right and hold
fi
rmly
(completely for a cold engine / appropriately less for a warm
engine).
4. Pull the reverse starter next to the handle
(Figure 3-3-(3))
.