Proline Promag L 400 HART
Technical data
Hauser
139
Transmitter cable entries
Order code for "Housing", option M "Compact, polycarbonate"; option N "Remote,
polycarbonate"
The various cable entries are suitable for hazardous and non-hazardous areas.
Electrical connection
Material
Cable gland M20 × 1.5
Plastic
Thread G ½"
via adapter
Nickel-plated brass
Thread NPT ½"
via adapter
Nickel-plated brass
Connecting cable for remote version
• Electrode cable: PVC cable with copper shield
• Coil current cable: PVC cable with copper shield
Sensor housing
• DN 50 to 300 (2 to 12"): aluminum coated AlSi10Mg
• DN 350 to 2400 (14 to 90"): carbon steel with protective varnish
Sensor connection housing
Aluminum coating AlSi10Mg
Sensor cable entries
Order code for "Housing", option N "Remote, polycarbonate"
The various cable entries are suitable for hazardous and non-hazardous areas.
Electrical connection
Material
Cable gland M20 × 1.5
Nickel-plated brass
Thread G ½"
via adapter
Nickel-plated brass
Thread NPT ½"
via adapter
Nickel-plated brass
Measuring tubes
• DN 50 to 300 (2 to 12"): stainless steel 1.4301/304, 1.4306/304L
• DN 350 to 2400 (14 to 90"): stainless steel 202, 304
Liner
• DN 50 to 300 (2 to 12"): PTFE
• DN 50 to 1200 (2 to 48"): polyurethane
• DN 350 to 2400 (14 to 90"): hard rubber
Electrodes
1.4435/304L, Alloy C-22