Proline Promag L 400 HART
Technical data
Hauser
123
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v
~
0.3/10 m/s
Full scale value current
output
(v
~
2.5 m/s)
Pulse value
(
~
2 pulse/s)
Low flow cut off
(v
~
0.04 m/s)
[mm]
[in]
[m
3
/h]
[m
3
/h]
[m
3
]
[m
3
/h]
200
8
35 to 1
100
300
0.05
5
250
10
55 to 1
700
500
0.05
7.5
300
12
80 to 2
400
750
0.1
10
350
14
110 to 3
300
1
000
0.1
15
375
15
140 to 4
200
1
200
0.15
20
400
16
140 to 4
200
1
200
0.15
20
450
18
180 to 5
400
1
500
0.25
25
500
20
220 to 6
600
2
000
0.25
30
600
24
310 to 9
600
2
500
0.3
40
700
28
420 to 13
500
3
500
0.5
50
750
30
480 to 15
000
4
000
0.5
60
800
32
550 to 18
000
4
500
0.75
75
900
36
690 to 22
500
6
000
0.75
100
1
000
40
850 to 28
000
7
000
1
125
–
42
950 to 30
000
8
000
1
125
1
200
48
1
250 to 40
000
10
000
1.5
150
–
54
1
550 to 50
000
13
000
1.5
200
1
400
–
1
700 to 55
000
14
000
2
225
–
60
1
950 to 60
000
16
000
2
250
1
600
–
2
200 to 70
000
18
000
2.5
300
–
66
2
500 to 80
000
20
500
2.5
325
1
800
72
2
850 to 90
000
23
000
3
350
–
78
3
300 to 100
000
28
500
3.5
450
2
000
–
3
400 to 110
000
28
500
3.5
450
–
84
3
700 to 125
000
31
000
4.5
500
2
200
–
4
100 to 136
000
34
000
4.5
540
–
90
4
300 to 143
000
36
000
5
570
2
400
–
4
800 to 162
000
40
000
5.5
650
Flow characteristic values in US units
Nominal
diameter
Recommended
flow
Factory settings
min./max. full scale value
(v
~
0.3/10 m/s
Full scale value current
output
(v
~
2.5 m/s)
Pulse value
(
~
2 pulse/s)
Low flow cut off
(v
~
0.04 m/s)
[in]
[mm]
[gal/min]
[gal/min]
[gal]
[gal/min]
2
50
10 to 300
75
0.5
1.25
–
65
16 to 500
130
1
2
3
80
24 to 800
200
2
2.5
4
100
40 to 1
250
300
2
4