Proline Cubemass C 100 HART
System integration
Hauser
51
Min. update period
Max. update period
Parameter overview with brief description
Parameter
Description
Selection / User entry
Factory setting
Burst mode 1 to n
Activate the HART burst mode for burst
message X.
• Off
• On
Off
Burst command 1 to n
Select the HART command that is sent to the
HART master.
• Command 1
• Command 2
• Command 3
• Command 9
• Command 33
• Command 48
Command 2
Burst variable 0
For HART command 9 and 33: select the
HART device variable or the process variable.
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
• Carrier mass flow
• Density
• Reference density
• Concentration
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
• Sensor integrity
• Pressure
• HART input
• Percent of range
• Measured current
• Primary variable (PV)
• Secondary variable (SV)
• Tertiary variable (TV)
• Quaternary variable (QV)
• Not used
Volume flow
Burst variable 1
For HART command 9 and 33: select the
HART device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 2
For HART command 9 and 33: select the
HART device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 3
For HART command 9 and 33: select the
HART device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 4
For HART command 9: select the HART
device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 5
For HART command 9: select the HART
device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 6
For HART command 9: select the HART
device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst variable 7
For HART command 9: select the HART
device variable or the process variable.
See the
Burst variable 0
parameter.
Not used
Burst trigger mode
Select the event that triggers burst message
X.
• Continuous
• Window
• Rising
• Falling
• On change
Continuous