Liquiline Control CDC90
Operation
Hauser
71
ID
Name
Function
9
Cleaner
Controls pump 1: cleaner connected
10
Water
Opens water valve
11
H2O + Service Pos.
Sealing water:
Opens water valve
Assembly moves to service position
12
H2O + Meas. Item
Sealing water:
Opens water valve
Assembly moves to measure position
13
H2O + Air Service
Opens water valve
Opens purge air
Assembly moves to service position
14
H2O + Air Meas.
Opens water valve
Opens purge air
Assembly moves to measure position
15
End + Service
Closes off supply of liquid and moves assembly to
service position
16
Buffer 4
Controls pump 3: connected canister with buffer
4
17
Buffer 7
Controls pump 2: connected canister with buffer
7
18
Wait
Pause
Closes all pilot valves. The assembly stays in the
last position to which it was moved.
This menu allows you to view and configure the contents of the individual program steps.
Path:Menu/Setup/Program step
Function
Options
Info
Program step
Select program steps
Program step name
Name program step
Pump selection
Select the pump: Only one pump can operate per
program step.