EDM01-06: DAG 3.7D Card User Guide
©2006
22
Version 1: March 2006
dag@endace:~$ dagclock –d dag0
muxin rs422
muxout none
status Synchronised Threshold 596ns Failures 0
Resyncs 0
error Freq 30ppb Phase -15ns Worst Freq 2092838ppb
Worst Phase 33473626ns
crystal Actual 100000023Hz Synthesized 67108864Hz
input Total 225 Bad 0 Singles Missed 1 Longest
Sequence Missed 1
start Thu Apr 28 14:55:20 2005
host Thu Apr 28 14:59:06 2005
dag Thu Apr 28 14:59:06 2005
Connecting the Time Distribution Server
The TDS 2 module connects to any DAG card with a standard RJ-45
Ethernet cable and can be placed some distance from a DAG card.
Existing RJ-45 building cabling infrastructure can be used to cable
synchronisation ports.
The TDS-2 and the DAG card synchronisation port should never be
connected to Ethernet or telephone equipment.
CAUTION: Never connect a DAG card and/or the TDS 2 module to
active Ethernet equipment.
Testing the Signal
For Linux and FreeBSD, when a synchronisation source is connected the
driver outputs some messages to the console log file
/var/log/messages
.
The
dagpps
tool is used to test a signal is being received correctly and is
of correct polarity. To perform the test, run:
dagpps –d /dag0.
The tool measures input state many times over several seconds, displaying
polarity and length of input pulse.
Some DAG cards have LED indicators for synchronisation (PPS) signals.
Summary of Contents for DAG 3.7D
Page 1: ......
Page 4: ...EDM01 16 DAG3 7D Card User Guide...
Page 6: ...EDM01 16 DAG3 7D Card User Guide 2006 vi Version 1 March 2006...
Page 12: ...EDM01 06 DAG 3 7D Card User Guide 2006 6 Version 1 March 2006...
Page 13: ...EDM01 06 DAG 3 7D Card User Guide 2006 7 Version 1 March 2006...
Page 30: ...EDM01 06 DAG 3 7D Card User Guide 2006 24 Version 1 March 2006...