OPTIONAL FBB5 SINGLE SPEED BLOwER INSTALLATION INSTRUcTIONS

OPTIONAL FBB5 SINGLE SPEED BLOwER INSTALLATION INSTRUcTIONS

2.  Remove air deflector by removing the four screws securing it 

to the blower assembly.

Figure 24

3.  Insert blower assembly into interior, bottom of firebox for De

-

luxe and Premium models and rear for Select models. Posi

-

tion blower assembly so that you align the notch on back of 

blower assembly with the center screw on firebox back, then 

push the blower assembly against firebox back. The blower 

wheel must be centered with the back wall of the firebox. The 

magnets on the back and bottom of blower assembly will suf

-

ficiently hold blower assembly in place.

4.  Once the blower assembly is in position, use a screwdriver to 

bend the upper right tab on the firebox away.

5.  Next, find the fan control switch and wire assembly. Feed the 

wires through the hole at the top of the firebox, and secure the 

fan control switch with the two screws provided. 

See Figure 

25.

Figure 25

6.  The fan control wires will slide down between the firebox and 

outer wrap near the blower assembly. 

See Figure 25.

7.  One fan control wire will have a 1/4” female terminal that must 

be attached to the open terminal on the blower motor. 

See 

Figure 28, connection A.

6.  The other fan control wire has a 1/4” male terminal. Attach this 

terminal to the open terminal on the blower power cord. 

See 

Figure 28, connection B.

9.  Route the wires away from moving parts of the blower assem

-

bly and retain wires together near the blower motor using the 

plastic purse clip provided.

10.  To complete the installation, plug the power cord into the junc

-

tion box receptacle at the right rear corner of the firebox outer 

wrap. 

See Figure 26.

Figure 26

11.  If room permits, the power cord can be located from the out

-

side of the unit looking through the junction box access hole 

(with the junction box removed), then plug up the power cord 

before reinstalling the pre-wired junction box.

12.  Once all connections are made electrically, it is recommended 

that you test the blower fan control operation by turning on 

power to the blower (Caution: 110 Volt). Then apply heat to 

the fan control switch inside the firebox with a lighter or match 

until blower is activated. Once blower is activated, check for 

proper operation. Do not place hands near blower assembly 

or other wiring while power is on.

13.  Replace blower access plate.

14.  This completes the installation of the optional FBB5 Blower kit 

accessory.

Note: 

This blower is equipped with a heat activated fan control 

switch. Blower will operate when the fireplace warms up, 

and will turn off automatically when the firebox cools down.

Blower Motor

The blower motor does not have oiling holes. Do not attempt to oil 

the blower motor.

Blower wheels

The blower wheels will collect lint and could require periodic clean

-

ing. If the air output decreases or the noise level increases, it indi

-

cates a dirty blower wheel. Remove fan and clean blower wheels.

warning:

 Unplugging of blower accessory will not stop the heat

-

er from cycling. To turn off gas to the heater (millivolt model): 

push in gas control knob slightly and turn clockwise to “OFF.” Do 

not force. To turn off gas on direct ignition model, turn gas line 

valve to “OFF.”

Figure 27

INDEX NO.

PART NO.

DEScRIPTION

1

R7731

BLOWER ASSEMBLY

2

R9901

FAN CONTROL SWITCH

3

R8147

WIRE ASSEMBLY

4

R7615

CORD SET

 

Figure 28

Summary of Contents for VFP32FB0F-5

Page 1: ...Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room Heaters WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to l...

Page 2: ... must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should show owner how to start and operate log set that is installed into firebox Important AllcorrespondenceshouldrefertocompleteModelNumber Serial Number Notice During initial firing of this firebox with a log set installed its paint will bake...

Page 3: ... be less than 84 inches to the bottom of the firebox See Figure 3 Mantel Clearances Vent free firebox models must use the hood supplied with the firebox or one of the optional hood kits available for each model If a combustible mantel is installed it must meet the clearance requirements detailed below Leave at least 36 inches clearance from the front of the firebox CLEARANCES Figure 1 Figure 2a Lo...

Page 4: ...sistance with this planning Planning Your Installation Please note that the optional VFA2 Fresh Air kit available for use with the Vent Free Firebox must be installed at the time of the initial installation Refer to pages 10 11 and 12 for detailed instructions for the air kit Accessory kits such as the FBB5 Blower kit Trim kits Mantles Full Cabinet Mantels plus other Decorative Frame Hood and Door...

Page 5: ... line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 inch hook up at the unit The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Gas access holes are provided on both sides of the firebox See Figure 11 When installing optional c...

Page 6: ...s shown in Figure 16 5 Push the handle for Open position and pull the handle for the Closed position See Figure 17 Figure 17 Completion of Air Kit installation 1 Determine the length of 4 inch diameter rigid or flex duct con nector installer supplied you will need from the firebox fire place to the exterior surface of the outside wall where the air kit hood will be installed Add a few extra inches...

Page 7: ...ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate pow er to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 20 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRI...

Page 8: ... complete the installation plug the power cord into the junc tion box receptacle at the right rear corner of the firebox outer wrap See Figure 26 Figure 26 11 If room permits the power cord can be located from the out side of the unit looking through the junction box access hole with the junction box removed then plug up the power cord before reinstalling the pre wired junction box 12 Once all con...

Page 9: ...each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control H...

Page 10: ...25447 25447 25447 BLOWER COVER PLATE 5 R7051 R7051 R7052 R7052 R7053 R7053 ROD SCREEN QUANTITY 2 6 20468 20468 21087 21087 33607 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R9293 R9293 R9293 HEARTH LEDGE LEFT 9 R9294 R9294 R9295 R9295 R9296 R9296 HEARTH LEDGE CENTER 10 23004 23004 23004 23004 23004 23004 HEARTH RETAINER 11 33026 33027 33028 33029 33030 3...

Page 11: ... optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional frame kit ac cessories Decorative Frame Kits Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional decorative door kit accessories ACCESSORIES continued Accessory Description Model Numbers Fan Kit Designed to provide...

Page 12: ... thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purch...

Page 13: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Reviews: