background image

LUNA 850 V / 550 V GOLD GAS

LUNA 850 DV / 550 DV GOLD GAS

                    INSTRUCTION FOR INSTALLATION AND USE

Passion for fire

English 09-2011

Summary of Contents for LUNA 850 V Gold Gas

Page 1: ...LUNA 850 V 550 V GOLD GAS LUNA 850 DV 550 DV GOLD GAS INSTRUCTION FOR INSTALLATION AND USE Passion for fire English 09 2011...

Page 2: ...A L L AT I O N I N S T R U C T I O N S F O R T H E M D E S I G N G A S F I R E P L A C E S T H E S U P P L I E R TA K E S N O R E S P O N S B I L I T Y F O R A N Y P O S S I B L E D A M A G E P O O R...

Page 3: ...12 5 INSULATION AND FINISHING 13 6 CONVECTION CURRENT 14 15 16 7 MOUNTING A 3 SIDED FRAME 17 8 POSITIONING THE LOGS DIAMOND SAPPHIRE AND WHITE PEBBLES 18 850 V 850 DV 19 21 550 V 550 DV 22 23 9 FIRST...

Page 4: ...STALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 4 OPEN CLOSING KEY IF SOME DUST OR WASTE IS SEEN ON THE WINDOW INSIDE AND OUTSIDE CLEAN THIS BEFORE THE FIRST USE OF THE FIREPLACE OPEN...

Page 5: ...f your order specifications this appliance is designed for natural or propane gas Read the instructions before installing and using this appliance Before installing the furnace please check the local...

Page 6: ...pic 2 A min 3 5 cm B 14 5 cm C min 18 cm The stove may not be placed direct ont the floor to allow natural convection The appertures for the air supply IN is situated underneath the appliances Regulat...

Page 7: ...astic 3 1 3 ELECTRICAL CONNECTION These appliances are equiped with a radiographic remote control making an earthened 220V socket necessary You should bear in mind that the appliance must be connectes...

Page 8: ...This is recommanded with a roof exit 3m TAB 1 This is recommanded with a roof exit 3m 150 100 Appliance C min C max Restrictiion HR as from 4m LUNA 850 V 550 V 3 m 18m 60 LUNA 850 DV 550 DV 3 m 18m 6...

Page 9: ...o use the sanitation set USSAN with placing This USSAN piece must be saeled at the roof ou of USDHC10 USDHC13 flex 100 ou 130mm 150 min 100 Aplliance C min C max Restriction HR as from 4m LUNA 850 V 5...

Page 10: ...Restriction HR 850 V 550 V 1 25m wall exit A 0 5m 75 850 DV 550 DV 1 25 wall exit A 75 A 200 130 in combination with B 150 100 after first curve Appliance A min B min B max Restriction HR 850 V 550 V...

Page 11: ...1 25m wall exit 75 A 8m 850 DV 550 DV 1 25 wall exit 75 A 7m 3 IMPORTANT BE CAREFULL EVERY HORIZONTAL PART DOES NOT HAVE AN NEGATIVE INCLINATION pic 5 IN DIRECTION OF OUTLET IT IS EVEN BETTER WHEN POS...

Page 12: ...V 550 DV for each 90 bend substract 1 m horizontaly or add 1 m verticaly 850 V 850 DV 550 V 550 DV for each 45 30 15 bend substract 0 5 m horizontaly or add 0 5 m verticaly FIG 5 150 100 with reducti...

Page 13: ...ck that it is working check the tightness of the gas pipe and the smoke pipe Once you have checked everything you can perform the final insulating and finishing operations The built in part of the fur...

Page 14: ...at some grids give off more heat than others and seeing that a hot air pipe functions in a manner similar to a chimney the one that is hot first has the most draught and therefore becomes hot even mor...

Page 15: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 15 OUT IN OUT IN OR INLET INLET Design Grill OUTLET 2 dm 4 dm...

Page 16: ...PLACED DIRECT ON THE STOVE MAY NOT BE PLACED DIRECT ON THE FLOOR WTHOUT THE FEETS THIS TO ALLOW NATURAL CONVECTION THE APPERTURES FOR THE AIR SUPPLY ARE SITUATED UNDERNEATH THE APLLIANCE EVERY OPENING...

Page 17: ...profile that is delivered with the fireplace pic 1 The 3 sided frame consist of 3 parts and are assembled to the Luna pic 2 the 3 sides frame and his 3 parts Fixing to frame with the included screws...

Page 18: ...u will have either a set of logs diamond sapphire or white pebbles There is an adequate supply of materials Our appliance is approved with these materials so please do not use other products Other dec...

Page 19: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 1 2 11 10 12 3 1 4 5 8 6 7 9 14 13 LUNA 850V 850DVGAS...

Page 20: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 20 LUNA 850V 850DV GAS...

Page 21: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 21 LUNA 850 V GAS GAZ Only for 850V with two burners Seulement pour appareil 850V avec deux br leurs en escaliers...

Page 22: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 22 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 LUNA 550 V 550 DV GAS...

Page 23: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 23 1 2 3 4 5 6 7 8 LUNA 550 V 550 DV GAS...

Page 24: ...s broken or cracked the appliance must not be used until the window has been replaced Contact your M Design reseller 10 SAFETY ADVICE AND MAINTENANCE Have your furnace inspected once a year by a quali...

Page 25: ...nsumption 12 USING THE MANUAL CONTROL BLACK BOX On the user interface a potentiometer is connected This one will be used only when the remote control is broken st DON T USE THE POTENTIOMETER SIMULTANI...

Page 26: ...20 30 37 50 28 30 Burner pressure mbar 23 8 19 3 29 36 36 28 2 Consumption m3 h 1 132 0 789 0 344 0 389 0 389 0 295 Burner injector Fr Re 6 x 0 80 6x0 75 6 x 0 80 6 x 0 5 6 x 0 6 6 x 0 6 6 x 0 6 6 x...

Page 27: ...ressure mbar 23 28 19 1 29 36 36 28 2 Consumption m3 h 1 132 1 026 0 344 0 389 0 389 0 295 Burner injector Fr Re 6x0 85 6x0 85 6x0 50 6x0 50 6x0 50 6x0 50 Pilot light injector 38 33A 38 33A 0 20P3 0 2...

Page 28: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 28 LUNA 850 V GOLD GAS...

Page 29: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 29 LUNA 850 DV GOLD GAS...

Page 30: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 30 LUNA 550 V GOLD GAS...

Page 31: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 31 LUNA 550 DV GOLD GAS...

Page 32: ...upper side frame above window 4 mm thickness frame 2 mm gap between frame and maconery Apperture to make L X 4mm 4mm 2mm 2mm H Y 2mm Connecting Flex tubes 1000H 1150H 1300H 2x obliged 1600H 4 x oblige...

Page 33: ...ided frame Two flexible tubes can be connected to one design grid 2 connections Connecting Flex tubes 1000H 1150H 1300H 2x obliged 1600H 4 x obliged 4 sided frame 3 5 7 or 10 cm X inside measurement f...

Page 34: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 34 4 sided frame X 3 5 cm X 7 cm X 10 5 cm onderlat baguette 35 70 105 Z X DETAIL Z...

Page 35: ...X TYP 28 00 GS X TYP 25 00 GS TYP 05 00 GS 06 04 GS X TYP 06 05 GS X TYP 06 03 GS 06 07 GS X 06 06 GS 06 08 GS X 06 09 GS X TYP 12 00 GS X 13 00 GS X TYP 02 02 00 GS X TYP 27 00 GS X TYP 10 00 GS X T...

Page 36: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 36 14 SPARE PARTS X 850DV 550DV...

Page 37: ...installation or repair by a third party including the buyer Heat cracks which normally occur in the mantel In cases where changes have been made to the furnace without our consent In cases where the b...

Page 38: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 38...

Page 39: ...INSTRUCTION FOR INSTALLATION AND USE LUNA 1000 1150 1300 1600 H GOLD GAS M DESIGN 39...

Reviews: