background image

33742-1-0614

Page 13

33742-1-0614

Page 12

OPTIONAL FBB5 SINGLE SPEED BLOwER INSTALLATION INSTRUcTIONS

OPTIONAL FRESh AIR KIT INSTALLATION INSTRUcTIONS

1

2

3

PARTS LIST

INDEX NO.

PART NO.

DEScRIPTION

1

29259

Outside Air Vent Assembly

2

29257

Slide Assembly

3

29263

Handle Retainer

Hardware Pack

Attention:

  It is recommended to install the blower assembly be

-

fore connecting gas inlet supply line.

wiring

The  appliance,  when  installed,  must  be  electrically  grounded  in 

accordance  with  local  codes  or,  in  the  absence  of  local  codes, 

with the

 National Electrical Code, ANSI/NFPA 70

,  if  an  external 

electrical  source  is  utilized. 

This appliance is equipped with 

a three-prong [grounding] plug for your protection against 

shock hazard and should be plugged directly into a properly 

grounded three-prong receptacle. Do not cut or remove the 

grounding prong from this plug. 

For an ungrounded receptacle, 

an adapter, which has two prongs and a wire for grounding, can be 

purchased, plugged into the ungrounded receptacle and its wire 

connected to the receptacle mounting screw. With this wire com

-

pleting the ground, the appliance cord plug can be plugged into the 

adapter and be electrically grounded.

caution: 

Label all wires prior to disconnection when servicing 

controls. Wiring errors can cause improper and dangerous op

-

eration. Verify proper operation after servicing.

Note:

  Junction box on right side of fireplace must be pre-wired at 

time of fireplace installation for use with blower assembly. 

A standard wall ON/OFF wall switch or optional SCV1 Vari

-

able Speed Control Kit should be installed to activate pow

-

er to the fireplace, and control the operation of the FBB5 

Blower assembly. It is recommended that installation of the 

wiring be performed by a qualified electrician. 

See Figure 

20.

1.  If installed, turn OFF gas supply to firebox/gas log.

2.  If applicable, turn OFF electric supply to firebox.

 

cAUTION:

 ALL WIRING SHOULD BE DONE BY A QUALI

-

FIED ELECTRICIAN AND SHALL BE IN COMPLIANCE WITH 

ALL LOCAL, CITY AND STATE BUILDING CODES. BEFORE 

MAKING  THE  ELECTRICAL  CONNECTION,  MAKE  SURE 

THAT  MAIN  POWER  SUPPLY  IS  DISCONNECTED.  THE 

APPLIANCE, WHEN INSTALLED, MUST BE ELECTRICAL

-

LY GROUNDED IN ACCORDANCE WITH LOCAL CODES, 

WITH THE NATIONAL ELECTRICAL CODE ANSI/NFPA 70 

(LATEST EDITION).

Figure 20

A factory installed junction box is located on the lower right 

side of the fireplace. Wiring must be fed to the junction box 

and  attached  to  the  receptacle  that  is  provided.  From  right 

side of the fireplace, remove the screw securing the junction 

box assembly. Leave approximately 6” of wire in the junction 

box for connection.

Attach black wire to one side of the receptacle and white wire 

to opposite side of receptacle. The ground wire should be at

-

tached to the green (ground) screw.

Attention:

  If  installed,  do  not  damage  gas  inlet  supply  line 

when blower assembly is inserted into firebox. In some cases, 

removal the gas inlet supply line may be necessary. 

For Vent Free Fireboxes

1.  Determine which type of firebox you have prior to installation. 

See Figures 21 through 23.

Deluxe Louvered Models

Figure 21 (Deluxe Louvered shown)

Deluxe Flush Face and Premium Models

Figure 22 (Deluxe Flush shown)

Select Firebox Models

Figure 23

Summary of Contents for VFP32FB0F-5

Page 1: ...Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room Heaters WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to l...

Page 2: ... must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should show owner how to start and operate log set that is installed into firebox Important AllcorrespondenceshouldrefertocompleteModelNumber Serial Number Notice During initial firing of this firebox with a log set installed its paint will bake...

Page 3: ... be less than 84 inches to the bottom of the firebox See Figure 3 Mantel Clearances Vent free firebox models must use the hood supplied with the firebox or one of the optional hood kits available for each model If a combustible mantel is installed it must meet the clearance requirements detailed below Leave at least 36 inches clearance from the front of the firebox CLEARANCES Figure 1 Figure 2a Lo...

Page 4: ...sistance with this planning Planning Your Installation Please note that the optional VFA2 Fresh Air kit available for use with the Vent Free Firebox must be installed at the time of the initial installation Refer to pages 10 11 and 12 for detailed instructions for the air kit Accessory kits such as the FBB5 Blower kit Trim kits Mantles Full Cabinet Mantels plus other Decorative Frame Hood and Door...

Page 5: ... line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 inch hook up at the unit The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Gas access holes are provided on both sides of the firebox See Figure 11 When installing optional c...

Page 6: ...s shown in Figure 16 5 Push the handle for Open position and pull the handle for the Closed position See Figure 17 Figure 17 Completion of Air Kit installation 1 Determine the length of 4 inch diameter rigid or flex duct con nector installer supplied you will need from the firebox fire place to the exterior surface of the outside wall where the air kit hood will be installed Add a few extra inches...

Page 7: ...ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate pow er to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 20 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRI...

Page 8: ... complete the installation plug the power cord into the junc tion box receptacle at the right rear corner of the firebox outer wrap See Figure 26 Figure 26 11 If room permits the power cord can be located from the out side of the unit looking through the junction box access hole with the junction box removed then plug up the power cord before reinstalling the pre wired junction box 12 Once all con...

Page 9: ...each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control H...

Page 10: ...25447 25447 25447 BLOWER COVER PLATE 5 R7051 R7051 R7052 R7052 R7053 R7053 ROD SCREEN QUANTITY 2 6 20468 20468 21087 21087 33607 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R9293 R9293 R9293 HEARTH LEDGE LEFT 9 R9294 R9294 R9295 R9295 R9296 R9296 HEARTH LEDGE CENTER 10 23004 23004 23004 23004 23004 23004 HEARTH RETAINER 11 33026 33027 33028 33029 33030 3...

Page 11: ... optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional frame kit ac cessories Decorative Frame Kits Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional decorative door kit accessories ACCESSORIES continued Accessory Description Model Numbers Fan Kit Designed to provide...

Page 12: ... thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purch...

Page 13: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...