background image

33742-1-0614

Page 9

33742-1-0614

Page 8

Locating Firebox

Place firebox in framing opening. Use the tabs on the side of the 
firebox to attach firebox to framing. Different tab locations can be 
used for finishing materials with thicknesses of 1/2 inch and 5/8 inch. 

See Figure 8.

Framing tabs should fit directly against framing material. Use at 
least one nail per bracket to secure in place.
Check squareness of the firebox prior to securing to framed opening. 

See Figure 9.

Figure 8

A black hood that is furnished with each firebox (or optional hood) 
MUST  be  installed  before  the  firebox  is  used.  Failure  to  do  so 
may  create  a  possible  fire  hazard. The  hood  is  located  behind 
upper  louver,  or  inside  the  firebox  on  flush  face  units.  If  brass, 
stainless steel, or hammered pewter hoods are desired, they can 
be purchased as an option. Attachment is the same as the standard 
black hood.

Flush Face Models

1.  On flush face models, loosely attach two screws (A) to hold the  

firebox top to face panel, then slide the hood flange between the 
firebox top and face panel and re-tighten the screws.

2.  Install one screw at each end of the hood as shown (C).

Louvered Models

1.  If you have a louvered model, remove upper louver.
2.  Place the top hood flange on top of the firebox, then install three 

screws through the firebox top from below and screw into the 
pilot holes in the hood flange (B).

3.  Install one screw at each end of the hood as shown (C).
4.  Re-install louver.

caution:

 The hood must be installed prior to operation of appliance. 

See Figure 10

Flush Face Models

Figure 10

Figure 9

FIREBOX INSTALLATION INSTRUcTIONS

INSTALLING hOOD

B

C

INNER FIREBOX TOP

Louvered Models

The firebox is designed to accept a 3/8-inch gas line for an approved 

vent-free gas logset. Have the line installed by a qualified service 

person in accordance with all building codes. Consult local building 

codes to properly size the gas supply line leading to the 3/8-inch 

hook-up at the unit. The state of Massachusetts requires that a 

flexible appliance connector cannot exceed three feet in length.
Gas access holes are provided on both sides of the firebox. 

See 

Figure 11

When  installing  optional  ceramic  fiber  side  panels  into  firebox, 

lay panel on a flat surface. Remove the gas line knockout (round 

depression) in the appropriate side panel using a drill or utility knife.
Check gas type. Use only the gas type indicated on the gas log 

set rating plate. If the gas listed on the plate is not your type of gas 

supply, DO NOT INSTALL. Contact your dealer for proper model.
Always use an external regulator for all LP fireboxes to reduce the 

supply tank pressure to a maximum of 14 inch w.c. This is in addition 

to the regulator fitted to the log set.

WARNING: CONNECTION DIRECTLY TO AN UNREGULATED 
L.P. TANK CAN CAUSE EXPLOSION.

 

Install only a ANSI Z21.11.2 vent-free burner and log set into this 
firebox. 

Figure 11

Extended hoods

If your non-combustible facing material is over 1" in thickness that will be used to finish this firebox, an extended hood is available that will 
extend out 2" farther out into the room. Contact your local dealer for details.

Finishing

All joints (top, bottom and sides), where the wall or decorative facing material meets the firebox surround should be sealed with a non-

combustible material. 

Hearth extensions are recommended, but not required for these  fireboxes.

VB4H32BL

Standard Black

VB4H36BL

Standard Black

VB4H42BL

Standard Black

VB4H32BR

Polished Brass

VB4H36BR

Polished Brass

VB4H42BR

Polished Brass

VB4H32SS

Stainless Steel

VB4H36SS

Stainless Steel

VB4H42SS

Stainless Steel

VB4H32HP

Hammered Pewter

VB4H36HP

Hammered Pewter

VB4H42HP

Hammered Pewter

INSTALLING hOOD

GAS LINE cONNEcTION

Brick Panel

Figure 12

A

C

A

C

Summary of Contents for VFP32FB0F-5

Page 1: ...Ventless Fireplace Enclosures for Gas Fired Decorative Type Unvented Room Heaters WARNING If the information in these instructions are not followed exactly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to l...

Page 2: ... must leave instruction manual with owner after installation 2 Installer must have owner fill out and mail warranty card supplied with firebox 3 Installer should show owner how to start and operate log set that is installed into firebox Important AllcorrespondenceshouldrefertocompleteModelNumber Serial Number Notice During initial firing of this firebox with a log set installed its paint will bake...

Page 3: ... be less than 84 inches to the bottom of the firebox See Figure 3 Mantel Clearances Vent free firebox models must use the hood supplied with the firebox or one of the optional hood kits available for each model If a combustible mantel is installed it must meet the clearance requirements detailed below Leave at least 36 inches clearance from the front of the firebox CLEARANCES Figure 1 Figure 2a Lo...

Page 4: ...sistance with this planning Planning Your Installation Please note that the optional VFA2 Fresh Air kit available for use with the Vent Free Firebox must be installed at the time of the initial installation Refer to pages 10 11 and 12 for detailed instructions for the air kit Accessory kits such as the FBB5 Blower kit Trim kits Mantles Full Cabinet Mantels plus other Decorative Frame Hood and Door...

Page 5: ... line installed by a qualified service person in accordance with all building codes Consult local building codes to properly size the gas supply line leading to the 3 8 inch hook up at the unit The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length Gas access holes are provided on both sides of the firebox See Figure 11 When installing optional c...

Page 6: ...s shown in Figure 16 5 Push the handle for Open position and pull the handle for the Closed position See Figure 17 Figure 17 Completion of Air Kit installation 1 Determine the length of 4 inch diameter rigid or flex duct con nector installer supplied you will need from the firebox fire place to the exterior surface of the outside wall where the air kit hood will be installed Add a few extra inches...

Page 7: ...ON OFF wall switch or optional SCV1 Vari able Speed Control Kit should be installed to activate pow er to the fireplace and control the operation of the FBB5 Blower assembly It is recommended that installation of the wiring be performed by a qualified electrician See Figure 20 1 If installed turn OFF gas supply to firebox gas log 2 If applicable turn OFF electric supply to firebox CAUTION ALL WIRI...

Page 8: ... complete the installation plug the power cord into the junc tion box receptacle at the right rear corner of the firebox outer wrap See Figure 26 Figure 26 11 If room permits the power cord can be located from the out side of the unit looking through the junction box access hole with the junction box removed then plug up the power cord before reinstalling the pre wired junction box 12 Once all con...

Page 9: ...each part from the fol lowing illustration and part list Be sure to give all this information Appliance Model Number Part Description Appliance Serial Number Part Number Type of Gas Propane or Natural Do not order bolts screws washers or nuts They are standard hardware items and can be purchased at any local hardware store Shipments contingent upon strikes fires and all causes beyond our control H...

Page 10: ...25447 25447 25447 BLOWER COVER PLATE 5 R7051 R7051 R7052 R7052 R7053 R7053 ROD SCREEN QUANTITY 2 6 20468 20468 21087 21087 33607 33607 HOOD 7 R9292 R9292 R9292 R9292 R9292 R9292 HEARTH LEDGE RIGHT 8 R9293 R9293 R9293 R9293 R9293 R9293 HEARTH LEDGE LEFT 9 R9294 R9294 R9295 R9295 R9296 R9296 HEARTH LEDGE CENTER 10 23004 23004 23004 23004 23004 23004 HEARTH RETAINER 11 33026 33027 33028 33029 33030 3...

Page 11: ... optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional frame kit ac cessories Decorative Frame Kits Available as optional kits in Brass Hammered Pew ter and Stainless Steel finishes Contact dealer for all avail able optional decorative door kit accessories ACCESSORIES continued Accessory Description Model Numbers Fan Kit Designed to provide...

Page 12: ... thermostat accessory or other part fail because of defective workmanship within one year from the date of purchase Empire will repair or replace at Empire s option Duties Of The Owner The appliance must be installed by a qualified installer and operated in accordance with the instructions furnished with the ap pliance A bill of sale cancelled check or payment record should be kept to verify purch...

Page 13: ...ms Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question please contact your dealer www empirecomfort com ...

Reviews: