background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16” XD Mk2 Inset Electric Fire

 

 

B-1005344

 

 

 

 

 

 

Packing Checklist

 

 

 

Electric Fire

 

Remote Control Handset*

 

Log Set

 

Ember Ice Crystal Set

 

Instruction Manual

 

Fascia

 

*THIS PRODUCT REQUIRES 2 X AAA BATTERIES FOR USE IN THE HANDSET (NOT SUPPLIED) 

IMPORTANT

 

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE 

INSTALLATION AND USE OF THIS ELECTRIC FIRE AND RETAIN 

FOR FUTURE REFERENCE.

 

 

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or learning disabilities, or lack of experience 
and knowledge, unless given supervision or instruction concerning use of 
the appliance by a person responsible for their safety.

 

 

 

 
 

Page 1

 

Summary of Contents for ELECTRIFLAME XD Mk2 B-1005344

Page 1: ...UPPLIED IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE INSTALLATION AND USE OF THIS ELECTRIC FIRE AND RETAIN FOR FUTURE REFERENCE This appliance is not intended for use by persons including children with reduced physical sensory or learning disabilities or lack of experience and knowledge unless given supervision or instruction concerning use of the appliance by a person responsible for...

Page 2: ...xed into a Chimney breast opening DO NOT insert or allow objects to enter any ventilation or exhaust openings on the appliance To prevent a possible fire do not block air intakes or exhaust openings in any manner DO NOT place this appliance near flammable materials surfaces or substances as there may be a risk of fire Keep flammable materials surfaces or substances at least 1 metre away from the f...

Page 3: ...ary Electricity Consumption at Nominal Heat Output 0 016 kW Auxiliary Electricity Consumption at Minimum Heat Output 0 016 kW Auxiliary Electricity Consumption at Standby Mode 0 0005 kW Type of heat Output Room Temperature Control With electronic room temperature control plus week timer Other Control Options With adaptive start control Manufacturers Name and Address BFM Europe Ltd Gordon Banks Dri...

Page 4: ...opening it is stable Important Notice To reduce heat losses and to prevent any chimney up draught affecting the operation of your fire we recommend that the chimney is blocked off From the front of the fire ensure that there is a minimum clearance of 50mm between any non combustible materials For combustible material clearances please consult with the manufacturer If there is any doubt regarding t...

Page 5: ...ply is capable of handling a load of 2000 watts 2kw Do not use an extension lead This appliance must be earthed Allow sufficient flex to enable the fire to be removed from the opening Always ensure that all electrical work complies with the relevant Building Regulations and the Electrical Code of Practice All electrical work should be carried out by a qualified electrician Laying the Log Embers Us...

Page 6: ...screws Arrange the remaining ember ice crystals along the front of the fire bed as shown below Fitting the Fascia The supplied fascia fits onto the front of the fire by either hooking the fascia brackets into the 4 slots on the outer trim of the appliance or by using the supplied magnets method dependent on model supplied Page 6 ...

Page 7: ...appliance ON or OFF into standby mode FLAME Pressing this button will cycle through the 4 different flame brightness levels HEATER Use this button to select Low Heat High Heat or heater OFF When LOW heat is selected the indicator light will glow amber for 10 seconds When HIGH heat is selected the indicator light will glow red for 10 seconds Please note the heater will only operate when the room te...

Page 8: ...ling schemes Ensure that the ON OFF Power Switch on the fire is in the ON position Point the remote control handset directly towards the fire and press the appropriate button to operate the fire Sliding the door down on the remote control will reveal the Smart Control panel which offers additional functions Otherwise using the basic remote buttons will operate the fire in the same way as the manua...

Page 9: ...e timer function allows up to 3 timers to be programmed for use over a 7 day period 1 Press the TIMER button to display the first timer and then press the SELECT button to adjust Timer 1 programme Set Time ON 2 The hour setting will now be blinking adjust using the time arrow buttons to the desired hour to switch on the fire and confirm using the SELECT button 3 The minute setting will now be blin...

Page 10: ... conjunction with the timer programmes When Adaptive Control is turned ON the fire monitors the room temperature in relation to the selected target temperature If the room temperature is sufficiently lower that the selected temperature the Adaptive Control facility will instruct the fire to switch on up to 10 minutes earlier than the set time to ensure the room is at the required temperature at th...

Page 11: ...st may be removed from the appliance with a soft dry cloth The exterior surface of the appliance can be cleaned with a soft damp cloth not dripping wet Dry the exterior surface before operating the heater Household glass cleaner can be used on the fire glass WARNING Do not immerse the heater in water Do not use any cleaning chemicals such as detergents and abrasives Do not allow the interior to ge...

Page 12: ... limited lifespan If a problem should occur the nature of the problem together with the date of purchase and installer information should be immediately reported to the retailer that the appliance was purchased from Proof of purchase will be required so the original invoice should be retained Issue 4 BFM Europe Ltd Gordon Banks Drive Trentham Lakes Stoke on Trent ST4 4TJ Technical Queries 01782 33...