background image

INSTALLATION & USER INSTRUCTIONS

All instructions must be handed to the user for

safekeeping.

MODELS COVERED BY THESE INSTRUCTIONS

WALL MOUNTED HIGH EFFICIENCY GAS FIRE

Please note : Except where otherwise stated, all rights,
including copyright in the text, images and layout of this
booklet is owned by Focal Point Fires plc.  You are not per-
mitted to copy or adapt any of the content without the
prior written permission of Focal Point Fires plc. 

1

Revision A - 10/11

©

2011 Focal Point Fires plc.

The products covered by this booklet are protected under
patent GB2275331C.

GB IE

BS EN 14829 : 2007

KM579167

Superior Fires

Christchurch, Dorset BH23 2BT

Tel: 01202 588 632     
Fax: 01202 499326

www.superiorfires.co.uk

e : [email protected]

IN THE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEER TO INSTALL, REPAIR OR SERVICE THIS APPLIANCE

CORINTHIA BLACK

CORINTHIA BLACK NG

F500373

CORINTHIA SILVER NG

F500374

MERIDIANA NG

F500375

MERRION NG

F500376

CORINTHIA SILVER

MERIDIANA

MERRION

Summary of Contents for CORINTHIA BLACK NG

Page 1: ...thout the prior written permission of Focal Point Fires plc 1 Revision A 10 11 2011 Focal Point Fires plc The products covered by this booklet are protected under patent GB2275331C GB IE BS EN 14829 2007 KM579167 Superior Fires Christchurch Dorset BH23 2BT Tel 01202 588 632 Fax 01202 499326 www superiorfires co uk e info superiorfires co uk INTHE UK ALWAYS USE A GAS SAFE REGISTERED ENGINEERTO INST...

Page 2: ...sed in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room On first light up of a new appliance burning off of high temperature paint and lubri cants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this sh...

Page 3: ...t ft3 by 35 3 This appliance may be installed in any room in the home except bathrooms In accordance with BS5871 part 4 installation in bed rooms is permitted If the appliance is to be installed in a bedroom then an electronic carbon monoxide detector complying with the current edition of BSEN 50291 must be installed in the same room as the appliance For maximum safety it is recommended that such ...

Page 4: ...y cause cracking along the joint line If the appliance is to be mounted on a dry lined wall or a timber framed construction wall then the integrity and ability of the wall to carry the weight of the appliance must be confirmed It is important in these circumstances that any vapour control bar rier is not damaged and that any structural members of the house frame are not damaged refer to section 7 ...

Page 5: ...only on a vertical surface Avoid sloped surfaces Installation onto anything other than a vertical wall may result in fire damage or injury If the appliance is to be mounted on the inner leaf of a conventional cavity brick wall or a solid wall then the wall plugs and fixing screws provided may be used Depending on the condition of the wall it may be necessary to use additional fixings In this situa...

Page 6: ... approximately ten seconds Now release the knob and the pilot should stay alight If the pilot is extinguished during use wait three minutes before repeating the ignition procedure To achieve the HIGH setting push the control knob in slightly and continue turning fully anti clockwise to the high position The main burner should light after a few seconds To decrease the setting to low turn the contro...

Page 7: ...is cold using a damp cloth and mild detergent on most surfaces Advise that on first light up of a new appliance initial curing of high temperature paint and burning off of lubricants may occur for the first few hours of operation During this period some smoke may be emitted from the outlet grille this should be no cause for concern Accordingly the room should be well ventilated with all windows an...

Page 8: ...he catalysts are inspected for signs of damage and dirt during routine servicing procedures The expect ed life of the catalysts is in excess of 11 000 hours 10 years of normal use After this time the catalysts should be replaced If there are any deposits of dirt or soot on the catalyst they should be cleaned with a soft brush and a vacuum cleaner If removed for cleaning ensure the seals are in goo...

Page 9: ...ere is a draft Fire is too close the an air vent Fire is sited on disused chimney breast which has not been adequately sealed up Dirt or lint in pilot aeration hole or on the lint gauze clean thoroughly If the pilot will not stay lit there could be a problem with contamination of the gas supply drafts room size and or ventilation or the thermocouple needs replacement Modifications are dangerous an...

Page 10: ...ucts The expected life of the catalyst is in excess of 11 000 hours 10 years of normal use After this time the catalyst should be replaced Should any home improvements be carried out to the property after the fire is installed such as installation of extractor fans for example the fire should be re checked by a competent person for safe operation U S E R I N S T R U C T I O N S 2 0 CLEARANCES TO C...

Page 11: ...e discoloured This appliance is intended as a secondary source of heat only and should not be used in a room without some form of background heating present If the appliance is used in a room as the sole source of heat then condensation may occur on colder surfaces within the room This appliance must not be used in bathrooms Refer to section 4 0 of the installation manual for guidance on installat...

Page 12: ...ridiana and Merrion models TRAY116 Burner unit Corinthia models TRAY111 Burner unit Meridiana and Merrion models F780079 Catalyst seal kit must also be supplied F940136 Seal kit for Catalyst 7 0 SERVICING 8 0 LIST OF REPLACEMENT PARTS 9 0 INSTALLATION DETAILS Installer GAS SAFE registration No Model Fire serial No Name contact details of installer Supplied by 10 0 SERVICE HISTORY Date of service S...

Reviews: