Page 28 / 30 EZM7750_ENG_VER11
Output function - 0
Counting Direction : 0 --> P (Counting to upwards)
BATCH Counter
Output function - 1
BATCH Counter
Counting Direction : 0 --> P (Counting to downwards)
When the actual value reaches to SET2 value each time, Op2 becomes active during
the period which is determined by Pro-17. There is a batch value which is incremented
+1 when the Op2 becomes active each time. When the batch value reaches to SET1
value, Op1 is active until the RESET. Counting continious until the RESET.
When the actual value reaches to “0” each time, Op2 becomes active during the
period which is determined by Pro-17. There is a batch value which is incre1
when the Op2 becomes active each time. When the batch value reaches to SET1
value, Op1became active and the device resets the batch value.
If the OP1 pulse time =0, the OP1 is always actives. If the OP1 pulse time !=0, Op1 is
inactive when the end of time.
When the actual value reaches to “0” each time, Op2 becomes active during the
period which is determined by Pro-17. There is a batch value which is incre1
when the Op2 becomes active each time. When the batch value reaches to SET1
value, Op1 is active until the RESET. Counting continious until the RESET.
Periodical
Reset
SET2
COUNT-0
Ch-A
OP-2
OP-1
(Periodical)
BATCH-0
SET1
BATCH-0
OP-1
(Indefinite)
Reset
SET2
COUNT-0
Ch-A
OP-2
OP-1
(Periodical)
BATCH-0
SET1
BATCH-0
OP-1
(Indefinite)