___________________________________________________________________________________________________
_________________________________________________________________________________________
Page 23 / 30 EZM7750_ENG_VER11
CHRONOMETER PARAMETERS:
PRO-02
Chronometer function and signal inputs
0- Total period measurement (ChA input)
1- Total pulse time measurement (ChA input)
2- Sum of the measured time period between the rising edges of ChA and ChB signals.
PRO-04
Contact Bounce for electrical noise. Adjustable from 0 to 250 miliseconds.
PRO-05
This parameter time base for Timer and Counter Mode.
0- From 00 hour 00 minute to 99 hours 59 minutes
1- From 00 minute to 00 second 99 minutes 59 seconds
2- From 00 second 00 milisecond to 99 seconds 99 miliseconds
3- From 00 hour 00 minute to 23 hours 59 minutes
4- From 000.00 hour to 999.99 hours
5- From 000.00 minute to 999.99 minutes
6- From 000.00 second to 999.99 seconds
PRO-06
Configuration for output functions. Refer to “Output Functions” for detail.
PRO-14
Output Function for module-1
0- Normally non-energised
1- Normally energised
PRO-15
Output Function for module-2
0- Normally non-energised
1- Normally energised
PRO-16
Energising time for Module-1. Adjustable from 0000.00 to 0099.99 seconds. Refer to “Output
Functions” for detail.
PRO-17
Energising time for Module-2. Adjustable from 0000.00 to 0099.99 seconds. Refer to “Output
Functions” for detail.
PRO-19
Selection counting direction.
0- 0 to PRESET
1- PRESET to 0
PRO-21
It’s determinates, actual value on the display saved or unsaved to memory when the energy
breaking.
0- Saved to memory. When the device energised, counting become from saved actual value.
1- Unsaved to memory. When the device energised, counting become from “0”.
PRO-23
Slave Address for serial communication bus. Adjustable from 1 to 247. The parameter value is “1”
for single device on the serial communication bus.
PRO-24
Configuration for MODBUS protocol.
0- MODBUS protocol is ASCII .
1- MODBUS protocol is RTU (Binary) .
PRO-25
Parity: 0-None, 1-Even, 2-Odd
PRO-26
Baud Rate: 0-1200 Bps, 1-2400 Bps, 2-4800 Bps, 3-9600 Bps, 4-19200 Bps
PRO-27
Stop Bits: 0- 1 Stop bit, 1- 2 Stop bit
PRO-28
Protection for RESET, SET-1 and SET-2 buttons on the front panel.
The parameter is adjustable 0 to 5.
0-Non protection. All buttons are active.
1-Only protection for RESET button is active.
2-Protection for SET1 and SET2 buttons are active.
3-Protection for SET1, SET2 and RESET buttons are active.
4-Only protection for SET1 button is active.
5-Only protection for SET2 button is active.
1
2
3
ON
OFF