36 • XM678D I&O Manual
026-1219 Rev 3
20 Technical Data
CX660 KEYBOARD
Housing
Self-extinguishing ABS
Dimensions
Case:
CX660 fascia
Front
: 35 mm x 77 mm
Depth
: 18 mm
Panel Mount:
29 mm x 71 mm panel cut-out
Protection
IP20
Frontal:
IP65
Power Supply
From XM600K power module
Display
Three (3) digits, red LED, 14.2 mm high
Optional Output
Buzzer
POWER MODULES
Case
8 DIN
Connections
Screw terminal block ≤ 1.6 mm
2
heat-resistant wiring and 5.0
mm Faston or screw terminals
Power Supply
24VAC -
An isolated transformer for the XM678D power
supply must be used. Do not share power with any other
devices.
Power Absorption
20VA max
Inputs
Up to 6 NTC/PTC/Pt1000 probes
Digital Inputs
Three (3) voltage-free
Relay Outputs (Total current on loads MAX 16A)
Refer to
Section 21
for UL Ratings
Solenoid Valve:
relay SPST 5A, 250Vac
Defrost:
relay SPST 16A, 250Vac
Fan:
relay SPST 8A, 250Vac
Light:
relay SPST 16A, 250Vac
Alarm:
SPDT relay 8A, 250Vac
Aux:
SPST relay 8A, 250Vac
Valve Output
Bipolar or unipolar valves
Maximum Distance between Controller and Valve
Up to 10m with shielded twisted cables, AWG 18
(0.823mm2) or less.
Maximum Length for LAN
Up to 30m with shielded twisted cables, AWG 20 (0.51mm2)
or less.
Optional Output (AnOUT)
Depending on the model
PWM/ Open Collector outputs:
PWM or 12VDC max
40mA
Analog Output:
4 to 20mA or 0 to 10V
Serial Output
RS485 with MODBUS-RTU and LAN
Data Storing
On the volatile memory (EEPROM)
Kind of Action
1B
Pollution Degree
2
Software Class
A
Table 20-1