4 – 15
Section 4 • Operation
VSS/VSM/VSH/VSSH • Installation, Operation and Maintenance Manual • Emerson • 35391SD
Figure 4-11. Vission 20/20
Configuration Screen - I/O
Configuration (Page 8)
Compressor Control with
Vission20/20™ Micro-controller (No
Slide Operation)
The Vission20/20™ panel can provide control for a single
screw compressor without slides as long as Analog Output
Board #10 is present and selected in the Configuration
screen, see FIgure 4-11.
The “No Slide“ operation will become active once the
correct type of compressor and model has been chosen,
see Figure 4-12.
The user must select either VSG/VSH or VSM from the
Compressor combo box in page 2 of the Configuration
Menu, and then the Model from the next box.
The choice of this type of compressor will cause the re-
frigerant combo box to be grayed out.
Once the compressor has been selected, the Vission
20/20™ panel touchscreen will show an indicator of VFD
speed percentage, and buttons to increase and decrease
it.
For more information on VFD capacity control, please
check the Vission20/20™ manual (35391SC).
WARNING
Software programming credentials shall only be
made available by the supplier. The user will only
have access to operational features established by the
supplier. Failure to comply may result in serious injury
or death.
FIgure 4-12. Compressor
and Model Setup with
Vission 20/20
Summary of Contents for Vilter VSH
Page 2: ......
Page 30: ...2 4 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 54: ...3 24 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 74: ...4 20 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 144: ...5 70 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 156: ...7 4 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 158: ...8 2 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 204: ...8 48 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 206: ...A 2 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 210: ...B 4 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 216: ...C 6 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 219: ......
Page 221: ......
Page 224: ......
Page 225: ......
Page 226: ......
Page 242: ...E 12 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 248: ...G 2 Blank VSS VSM VSH VSSH Installation Operation and Maintenance Manual Emerson 35391SD ...
Page 249: ......